Maintenance Objects 
3-507DIG-LINE (Digital Line) 
3
Notes:
a. Could experience a noisy port or link. This is an off-board problem 
detected by the port circuit. Check for defective wiring, a defective voice 
terminal, or move voice terminal closer to the switch (in terms of feet of 
wire from the jack to the switch). If the problem still exists, replace the 
circuit pack. Once the problem has been resolved, the alarm will be 
retired after a predetermined amount of time.
b. This Error Type and Aux Data will occur when at least 15 off-board 
problems have been detected with the link to the terminal. When an error 
with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board 
problem detected by the port circuit. Check for defective wiring, a 
defective voice terminal, or move voice terminal closer to the switch (in 
terms of feet of wire from the jack to the switch). If the problem still exists, 
replace the circuit pack. Once the problem has been resolved, the alarm 
will be retired after a predetermined amount of time.
c. This error type is logged when the port in question is busied out by 
maintenance personnel. Make sure port is released from busyout via the 
release port PCSSpp
 command.
d. This error type indicates that the circuit pack has been removed or has 
been insane for more than 21 minutes. To clear the error, reinsert or 
replace the circuit pack.
e. Problems transmitting to the voice terminal. This problem can be caused 
by defective wiring. Defective wiring can cause varying degrees of 
problems on different types of sets. Sets such as the 7410 appear to be 
more susceptible to wiring problems than other sets. This is usually an 
on-board problem and can be ignored if no user complaints are received.
f. This is an in-line event that produces this error type when a favorable 
response is received from running the Digital Line Electronic Power Feed 
Test (#11). No craft action is necessary. This alarm will be resolved with 
the passing of time.
g. With Aux Data 40963, this error type is a result of an unfavorable response 
to the Electronic Power Feed/ Positive Temperature Coefficient Test (#11). 
With Aux Data 40988, this error type indicates that the EPF/PTC circuit has 
been turned off due to an overcurrent condition.
For TN754 vintage 13 or earlier, the EPF circuit senses an overcurrent 
condition at the voice terminal. Check for a short in the wiring, a damaged 
jack, an incorrect type of voice terminal, or a defective voice terminal.
For TN754 vintage 14 or later, TN754B and TN2136, the PTC will open if 
there is a short on the power line for 1/2 second or longer. The voice 
terminal is probably not operating properly. Unplug the voice terminal for 
30 seconds and then plug it back in. If the voice terminal still does not 
operate, then check for a short in the wiring, a damaged jack, an incorrect 
type of voice terminal, or a defective voice terminal.