Maintenance Objects 
3-465DID-DS1 (DS1 DID Trunk) 
3
1004 ABORT The port was seized by a user for a valid call. Use the display port 
PCSSpp command to determine the trunk group/member number of the 
port. Use the status trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. You must wait until the port is idle before 
retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a 
maximum of 5 times.
1020 ABORT The test did not run due to a previously existing error on the specific port 
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack: 
1281—Loss of signal, 1793—Blue Alarm, 2049—Red Alarm, 2305—Yellow 
Alarm, 1537—Hyperactivity.
Look for the above error types in the Hardware Error Log and follow the 
procedures given in the appropriate DS1-BD or UDS1-BD maintenance 
documentation for the listed error types.
ANY FAIL The test failed. This can be due to on-board or off-board problems. 
Off-board problems of concern include EXP-PN and EXP-INTF faults, 
TDM-BUS faults, and faults associated with the tone detectors/tone 
generators. Clear all off-board problems before replacing the board. Keep 
in mind that a TDM-BUS problem is usually the result of a faulty board 
connected to the backplane or bent pins on the backplane.
1. Look for EXP-PN and/or EXP-INTF errors in the error log. If present, 
refer to the EXP-PN and the EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the 
TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present, 
refer to the TONE-BD and the TONE-PT Maintenance documentation.
4. Retest when the faults from steps 1, 2, and 3 are cleared. Replace the 
board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles 
on this port should be investigated using other port tests and by 
examining station, trunk, or external wiring.
Table 3-197. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page