Maintenance Objects 
3-448DATA-CHL (Data Channel) 
3
FAIL c. If the result of Test #107 is PASS and the result of Test #108 is PASS, 
then the target DATA-CHL is defective.
1. Issue the remove data-module command.
■ Replace the Processor circuit pack at your earliest convenience. 
After the Processor circuit pack has been replaced, its 
Time-of-Day clock must be set using the set time command.
2. Restore any busied out function (PRI-CDR/SEC-CDR, 
SYS-PRNT, PMS-PRNT/JNL-PRNT, PMS-LINK) to service 
before moving on to another activity.
PASS The target DATA-CHL is functioning. Connections can be established over 
the target DATA-CHL.
Table 3-189. TEST #111 Data Channel Local Loop Back Test — Continued
Error 
Code
Test 
Result Description/Recommendation
Continued on next page