1-75Install DS1 CPE Loopback Jack (T1 Only) 
1
9. Repeat Steps 5 through 8 as desired to observe bit error rate 
characteristics. Also, wait 1 to 10 minutes between Steps 5 through 7. One 
minute without errors translates to better than a 1 in 10 to the eighth error 
rate. Ten minutes without errors translates to better than a 1 in 10 to the 
ninth error rate.
10. If the test runs for 1 minute with an error count of 0, confirm that the 3-in-24 
pattern error detector is operating properly by entering 
test ds1-loop 
<location> inject-single-bit-error
. This causes the 3-in-24 pattern 
generator on the DS1 circuit pack to inject a single-bit error into the 
transmit pattern. A subsequent 
list meas ds1 summary <location> 
command displays the bit error count. If a count greater than 1 is 
displayed, replace the ICSU and retest. If the problem continues, replace 
the DS1 circuit pack.
11. Terminate the test by entering 
test ds1-loop <location> end 
cpe-loopback-jack-test
. Wait about 30 seconds for the DS1 to re-frame 
on the incoming signal and clear DS1 facility alarms.
Loopback termination fails under the following conditions:
a. The span is still looped somewhere. This could be at the loopback 
jack, at the ICSU, or somewhere in the network. This state is 
indicated by a fail code of 1313. If the red LED on the loopback 
jack is on, replace the ICSU. Re-run the test and verify that the 
loopback test terminates properly. If not, replace the DS1 circuit 
pack and repeat the test.
Bit Error Count Cumulative 
count of 
detected 
errors
If there are no wiring problems, the counter 
remains at 0.
A count that pegs at 65535 or continues to 
increment by several hundred to several 
thousand on each list meas command execution 
indicates intermittent or corroded connections, 
severe crosstalk, or impedance imbalances 
between the two conductors of the receive pair or 
the transmit pair. Wiring may need replacement.
Note that “ESF error events” counter and the ESF 
performance counter summaries (“errored 
seconds”, “bursty errored seconds”, and so forth) 
will also increment. These counters are not used 
with the loopback jack tests. However, they will 
increment if errors are occurring. Counters should 
be cleared following the test.
Table 1 -7 . DS1 Span Troubleshooting — Continued
Displayed 
Field Function Indication
Continued on next page