User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-444DATA-CHL (Data Channel) 
3
Data Channel Local Loop Back Test (#111)
This test verifies the integrity of the dual port RAM that is shared between the 
software and hardware that composes the DATA-CHL. The dual port RAM is 
placed in local loop back mode such that data to be sent by the DATA-CHL is 
instead looped back to be received by the DATA-CHL. The loop back is done 
within the dual port RAM, that is, the data is never sent over the TDM Bus. The 
test checks that the data received by the DATA-CHL is the same as the data that 
was sent by the DATA-CHL.
NOTE:
If an Error Code is encountered that recommends that an CDR Link, System 
Printer Link, PMS Log Printer, Wakeup-Log Printer, and/or PMS Link be 
busied out, restore each busied-out link to service according to the 
PRI-CDR/SEC-CDR (PRI-CDR Link), SYS-PRNT (System Printer Link), 
PMS-PRNT/JNL-PRNT (PMS Printer Link), or PMS-LINK (Property 
Management System Link) Maintenance documentation, respectively, 
before concluding work on the problem.
PASS The target DATA-CHL, Processor circuit pack, TDM Bus (TDM-BUS), and 
Tone-Clock circuit pack (TONE-BD, TONE-PT, TDM-CLK) are functioning. 
Connections can be established over the target DATA-CHL.
Table 3-188. TEST #110 Data Channel Crosstalk Test — Continued
Error 
Code
Te st 
Result Description/Recommendation
Continued on next page