Switch Router Adapter Owner's Manual
2-24 October 22, 1999  SP Switch Router Adapter Guide - 1.4 Update 2
Configuring the SP Switch Router Adapter
Step 3. Change profile settings
Step 3. Change profile settings 
Specify card-level parameters – Card profile   
Set specific dev1 card configuration parameters at the Card profile. The fields to set are:
– OPTIONAL: specify ICMP throttling settings 
– OPTIONAL: change run-time binaries 
– OPTIONAL: change dump variables 
This is the card profile for the SP Switch Router Adapter card residing in slot 8. Media card 
type, dev1, is automatically read into the read-only media-type field. Other values shown 
are defaults. At the top level, you see config and ICMP throttling fields: 
super> read card 8
CARD/8 read
super> list card 8
card-num* = 8
media-type = dev1
debug-level = 0
hssi-frame-protocol = Frame-Relay
sonet-frame-protocol = PPP
ether-verbose = 0
ports = <{ 0{off on 10 3} {single off} {"" "" 1 sonet internal-osc+
load = { 0 < > 1 0 0 } 
dump = { 0 < > off off}
config = { 0 1 1 4 0 0 }
icmp-throttling = { 10 10 2147483647 10 10 10 }
Specify ICMP throttling 
You can specify ICMP throttling changes for this card in these settings. Refer to Chapter 1 in 
the GRF Configuration and Management manual for an explanation of each field, or do a set 
<field-name>?
 for a brief description. Default values are shown:
super> list ic
echo-reply = 10
unreachable = 10
redirect = 2147483647
TTL-timeout = 10
param-problem = 10
time-stamp-reply = 10
Change default echo reply and TTL settings with this series of commands:
super> set echo-reply = 4 
super> set TTL-timeout = 12 
super> write 
CARD/8 written
You do not have to do a write until you have finished all changes in the Card profile. However, 
you get a warning message if you try to exit a profile without saving your changes.