18-18 Preliminary May 9, 2000  APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide
Signaling System 7 (SS7)
Configuring an SS7 signaling gateway
Command output showing errors
The following sample indicates that errors were detected in SS7 connections:
admin> ss7asg -s
SS7 Signaling Gateway interface statistics:
 Initialized successfully:  Yes
 Interface state:  Enabled/Down
 Diagnostic level:  0
Errors:
 Number of memory allocation failures: 0
 Number of errors in profile operations: 0
 Number of invalid memory pointers: 0
 Number of internal errors:  8
Initialization Errors:
 Number of errors in initialization: 8
 Memory pools:  0
 Mailboxes:  0
Signaling Layer:
 Number of SETUP requests from:  L2: 0 CC: 0
 Number of CONNECT to ASG:  0
 Number of CONNECT_ACK from ASG:  0
 Number of SETUP rejected from:  L3: 0 CC: 0
 Number of DISCONNECT requests from: L2: 0 CC: 0
 Number of REGISTRATION to ASG:  0
 Number of REGISTRATION_ACK from ASG: 0
 Number of DL_REL_IND from L2:  0
 Number of DL_EST_IND from L2:  0
 Number of T303 expiry events:  0
 Number of T305 expiry events:  0
Number of link fail-overs
In a dual LAN configuration, the number of times the 
TAOS unit switched from one TCP/IP messaging link to 
another due to the failure of the link.
Number of persistent 
errors
Number of times the TAOS unit tried to reestablish a 
layer 2 link. 
Last error
Type of last error. Possible values are:
• No Error: L2 is operating normally.
• Link Loss: Link down.
• Persistent Error: Link down.
• Link Shutdown: Link disabled.
• Link Fail-over: Switched to secondary LAN 
connection.
Last error status change 
timestamp
Time the last error occurred.
Output field Description