Installation Guide
Installation Instructions
4 | P a g e v 1 . 0 p u b l i s h e d o n 0 6 2 0 1 7
SENSOR SETTINGS:
DURATION TIME: The length of time the light will remain switched on after activation can be adjusted from 10secs ±5
to 4mins ±1. Rotating the time from (+) to (-) will reduce the duration time.
NOTE: Once the light has been triggered by the PIR sensor, any subsequent detection will start the timed period again
from the beginning, the light will remain on until there is no movement detected.
ADJUSTING THE SENSITIVITY: The sensitivity means the maximum distance which
PIR Sensor can be triggered by movement body. Turning the SENS knob + to - will
decrease the sensitivity.
LUX LEVEL: The lux control module has a built-in sensing device (photocell) that
detects daylight and darkness. The () position means that the fitting will work at both
day and night. The () position will only work at night.
NOTE: If you want to test the detection area of the PIR sensor, please wait for the
ambient light level is below 20 lux.
SENSOR TESTING:
1. Put the LUX control knob to the light () position and the TIME control knob to minimum (-). Turn the wall switch
on and the light will turn on and remain on for about 50 seconds for the “warm-up” mode. After this initial “warm
up” mode the light will turn off and the fitting will be in AUTO MODE.
2. Direct the sensor toward the desired area to be scanned by twisting the sensor left and right.
3. Have someone walk across the centre of the area to be scanned and slowly adjust the angle of the sensor until
the fitting can sense the moving person and causes the light to switch on.
4. Adjust the TIME control knob to the desired length of time for the fitting to remain on.
5. Adjust the LUX control knob to achieve the ideal ambient light for the fitting to switch “on”.
For the fitting to switch ‘on’ when the ambient light is darker, switch the LUX control knob from () to ().
For the fitting to switch ‘on’ when the ambient light is brighter, switch the LUX control knob from () to ().
You may need to make further adjustments to achieve your ideal light level setting.
MANUAL MODE: (Sensor Override Function)
Manual mode is used when you want the LED lights to be constantly on. The PIR sensor will be disabled and not affected
by the duration time and lux level settings. The maximum duration for manual mode is 8 hours.
1. During normal use the wall switch is in the ON position and the fitting is in AUTO MODE with the PIR sensor detecting
any movement and the LED lights will switch on and off accordingly.
2. To switch into MANUAL MODE, turn the wall switch off and on twice within three seconds.
Wall switch action: OFF → ON → OFF → ON.
Wait for 3 seconds and the LED lights will turn on and the fitting will be in MANUAL MODE.
NOTE: If the wall switch action is done only once or more than twice, the fitting will not enter into MANUAL MODE.
3. To change back to AUTO MODE, turn the wall switch off and on twice within three seconds.
Wall switch action: OFF → ON → OFF → ON.
NOTE: During MANUAL MODE or AUTO MODE, by switching off the wall switch for about 15 seconds this will
reset the sensor mode.
Turn the wall switch on again and the PIR sensor will enter into the “warm-up” mode and the LED lights will
remain on for about for 50 seconds. After this the LED lights will turn off and the fitting will be in AUTO MODE.