Installation Guide

Installation Instructions
2 | P a g e v 1 . 0 (06 / 2 0 2 2 )
NOTE: Testing cannot account for installation variables such as variation in mains supply voltage, cable capacitance,
electrical noise, transients, surges and ripple control signals (commonly found in NSW & QLD).
NOTE: The information provided is correct to the best of Beacon Lighting’s knowledge at the date of publication.
This recessed luminaire has an insulating ceiling type IC-4 rating. Building insulation material can safely be exposed
continuously to temperatures up to 90°C may abut and cover the luminaire. (Please refer to the Clearance
Information section and the IC-4 rating section in this instruction manual for further details.)
If loose fill insulation or thermal insulation is not fixed into position or if there are loose combustible materials (e.g.
leaves or combustible materials stored in the roof space), a barrier or guard is required as per the Clearance
Information section in this instruction manual.
The LED driver must be placed at least 100mm away from the LED downlight module to allow for cooling.
The LED driver can be placed under the insulation. (Please refer to the Clearance Information section in this
instruction manual for further details.)
The LED downlight module is only suitable for use with Lucci LED Driver
model#: LB-PD-2621-11.5W.
The recessed luminaire must not be used if the diffuser has been cracked or damaged.
Take care not to pull any electrical wires during unpacking as this may damage the connection.
Lay out all the components on a smooth surface and make sure no components are missing before assembling.
If parts are missing, return the complete product to the place of purchase for inspection or replacement.
Check whether the recessed luminaire has been damaged during transport. Do not operate/install any product
which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or
replacement.
Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work.