Owner's manual

20
To configure alarm settings:
1 Under I/O CHANNEL, select NO (Normal Open), NC (Normal Closed), or OFF. Click
NEXT PAGE to view additional channels (8-channel models only).
2) Apply loss alarms to the following:
HDD LOSS: The alarm will sound if the internal HDD is damaged
HDD SPACE: The alarm will sound when the HDD is full (overwrite must be disabled)
VIDEO LOSS: The alarm will sound when a camera is disconnected
3) Under ALARM MANAGE, configure the following:
OUTPUT: Set the output time (in seconds) on the spot monitor from 0s, 10s, 20s, 40s,
or 60s.
BUZZER: Set the time (in seconds) for the buzzer when an alarm is triggered0s,
10s, 20s, 40s, or 60s
NOTE: Set the buzzer to 0s if you want to disable the alarm during motion detection
DURATION: Set the time (in seconds) for the system to record after a triggered alarm
0s, 10s, 20s, 40s, or 60s
EMAIL SETUP
The system can send an email notification with a JPEG snapshot for triggered events on the
system.
To setup email notification:
1) Under EMAIL, select ON.
2) Under SSL, select OFF.
NOTE: SSL deals with encryption. Only advanced users should enable this option.
3) Under SMTP PORT, enter the SMTP port of your email server.
4) Under SMTP, enter the SMTP address of your email server. For example,
smtp.gmail.com
5) Under SEND EMAIL, enter the sender email address.
6) Under SEND PW, enter the password of your email server.
7 Under RECV EMAIL, enter the email address that will receive the email notification.
8 Click APPLY. Click CLOSE in the confirmation window.
9) Click EXIT in all menus until all windows are closed.