Manual

>>Stand-alone DVR User Manual
23
>
PrerecordSet the prerecord time. After motion detect triggered alarm,
>
Recording durationAfter motion detect triggered alarm, system will on-going record for the
set duration time
>
Area settingSet the motion detect area. Press setup button to enter the setup interface, as
below:
Pic.26 Video detect area setting
Area settingpress direction button to move the curser to the detected area starting point, and
press “Enter” button to confirm it, refer to the “1” position on above picture.
After the confirmation of starting point, press direction button to set the detecting area, refer to the
“2” position on above picture. Press “Enter” button to finish the setting, the selected area will
become to green color, refer to the “3” position on above picture. Use same method to set other
detecting area.
Area EditMoving the selection box to the appropriate location in the selected area, use
above-mentioned area selection way to edit the detection area.
Apply to all channels: Apply this video detection parameter setting to all channels.
Sensor
Set sensor trigger timeassociate alarm and associate recording channel etc. Setting interface as below
a) Sensor channel No.select sensor input channel number116
b)
Trigger onUnlock sensor trigger
c)
Trigger scheduleSet the trigger time periods
d)
Associate ChannelSet alarm trigger associate recording channel
>
Prerecord timeSet the prerecord time. After sensor triggered alarm, system will ahead of
“prerecord time” to start the recording
>
Recording durationAfter sensor triggered alarm, systems will on-going record for the set
duration time.
e)
Alarm associate
>
Sound promptAfter triggered alarm, system will output “du…du …”warning tone.
>
BuzzerAfter triggered alarmthe buzzer on the machine will output “Di ...Di... Di” warning
tone.
>
RelayAfter triggered alarmsystem will close the switch of relay to connect the outer alarm
system.
>
Alarming DurationSet the alarm duration. After triggered alarm, system will output the alarm
signal till you clean it by manual or the end of pre-setting alarm duration.
f)
Apply to all channel: Apply this channel sensor parameter settings to all channels.