2.2.2.5.1 ALARM SETUP
Move the cursor toALARM SETUP】(Icon highlighted when selected),pressEnter
to access setting interface.
I/O CHANNEL
Each channel corresponds an I/O status, which means when an alarm is
triggered, it will activate the corresponding channel to start alarm recording.
N.Oindicate I / O input level from high to low
N.Cindicate I / O input level from low to high
HDD LOSS
ON: means it will trigger an alarm if there is no HDD, and a Hwill be displayed
on the left bottom of channel 1 in the live view
HDD SPACE
ONIf the space is less than 500M, a remark will appear in live viewNot enough
space, please change HDD after shutdown.
VIDEO LOSS
ONwhen one channel has no video input, it will display “video loss” in live view.
ALARM MANAGE
Includes three options, alarm output, buzzer and post REC.
OUTPUTWhen an alarm is triggered, the alarm output time will be:
0 second10 seconds, 20 seconds, 40 seconds and 60 seconds
BUZZERBuzzer calling time setup when alarm is triggered: 0 second,10
seconds,20 seconds,40 seconds and 60 seconds
POST REC.Post recording time setup: 30 seconds,1 minute,2 minutes and 5
minutes
PRE RECPre-recording time is fixed as10 seconds.
2.2.2.5.2 SYSTEM INFO
Move the cursor toSYSTEM INFOIcon highlighted when selectedpressEnterto
access setting interface. This interface mainly displays system hardware features and firmware
versions; includes : device type, software version, MAC address, serial number.
20