Logic PCI to Dual Channel SCSI Host Adapter User's Guide
A-2 Technical Specifications
Figure A.1 LSIU40HVD Mechanical Drawing
A.1.2 Electrical Characteristics
The LSIU40HVD maximum power requirements, including SCSI
TERMPWR, under normal operation are as shown in Table A.1.
Under abnormal conditions such as a short on SCSI TERMPWR, + 5 V
current may be higher. At temperatures of at least 25 ˚C, a current of 4 A
is sustained no longer than 30 seconds before the self-resetting
TERMPWR short circuit protection device opens.
The PCI PRSNT1/ and PRSNT2/ pins are set to indicate a 15 W
maximum configuration.
J2
J4
J5
J7
TP5
TP1
J3
J6
TP3
TP6
NVRAM
FLASH
EEPROM
TERMPWR
Fail LED
TP2
NVRAM
TERMPWR
Fail LED
All Dimensions are given in millimeters and (inches)
LSI53C876
J1
190.50 (REF) (7.50 (REF))
96.52 (REF) (3.80 (REF))
Table A.1 Maximum Power Requirements
+5 V DC ±5% 1.5 A Over the operating range 5 ˚C to 55 ˚C.
+3.3 V DC ±0.3 V 130 mA Over the operating range 5 ˚C to 55 ˚C
when operating in a 3.3 V PCI slot.