Chapter 2: Hardware and Software Setup
Cabling Configurations
Figure 7 Adding a Second JBOD Enclosure - Redundant Configuration
The steps for adding the second JBOD enclosure are as follows:
1. Connect a link from connector 2 on Expander B of JBOD enclosure A to connector 1 on expander B of JBOD
enclosure B.
2. Disconnect the link from connector 1 on expander A of JBOD enclosure A and reconnect it to connector 1 on
expander A of JBOD enclosure B.
3. Disconnect the link from connector 0 on expander A of JBOD enclosure A and reconnect it to connector 0 on
expander A of JBOD enclosure B.
4. Connect the link from connector 2 on expander A of JBOD enclosure B to connector 0 on expander A of JBOD
enclosure A.
?