4.9.8 SCSI Firmware
The MegaRAID SCSI 320-1 firmware handles all RAID and SCSI
command processing and also supports the features listed in Table 4. 7.
4.10 RAID Management
RAID management is provided by software utilities that manage and
configure the RAID system and MegaRAID SCSI 320-1, create and
manage multiple disk arrays, control and monitor multiple RAID servers,
provide error statistics logging, and provide online maintenance. They
include:
· MegaRAID BIOS Configuration Utility
· WebBIOS Configuration Utility
· Power Console Plus
· MegaRAID Manager
4.10.1 MegaRAID BIOS Configuration Utility
The BIOS Configuration Utility (<Ctrl><M>) is used to configure and
maintain RAID arrays, format hard drives, and manage the RAID system.
Table 4.7 SCSI Firmware
Feature Description
Disconnect/
reconnect
Optimizes SCSI bus seek
Tagged command
queuing
Multiple tags to improve random access
Scatter/gather Multiple address/count pairs
Multi-threading Up to 255 simultaneous commands with elevator sorting
and concatenation of requests per SCSI channel
Stripe size Variable for all logical drives: 2, 4, 8, 16, 32, 64, or
128 Kbytes
Rebuild Multiple rebuilds and consistency checks, with user-
definable priority