User`s guide
1-14 Overview
Copyright © 2009 by LSI Corporation. All rights reserved.
Step 2. Turn off power to the server and all drives, enclosures, and
system components. Disconnect the power cords from
the systems.
Step 3. Open the host system by following the instructions in the host
system technical documentation.
Step 4. Either remove the SAS cable connectors from the internal
drives, or remove the shielded cables from the external drives
that you want to migrate.
a. Make sure that pin 1 on the cable matches pin 1 on the
connector.
b. Make sure that the SAS cables conform to all SAS
specifications.
Step 5. Remove the drives from the first system, and insert them into
drive bays on the second system.
Step 6. Connect the SAS cables to the drives in the second system.
Step 7. Determine the SAS target requirements.
Step 8. Perform a safety check.
a. Make sure that all of the cables are attached correctly.
b. Make sure that the RAID controller is installed correctly.
c. Close the cabinet of the host system.
Step 9. Reconnect the power cords to the system.
Step 10. Turn on the power to the system.
The controller detects the RAID configuration from the
configuration data on the drives.
1.7 Hardware Specifications
You can install the MegaRAID 6Gb/s SAS RAID controllers in a computer
with a motherboard that has a PCI Express slot. Ta bl e 1 .1 describes the
hardware configuration features for the MegaRAID 6Gb/s SAS RAID
controllers.










