User`s guide

1-6 Overview
Copyright © 2009 by LSI Corporation. All rights reserved.
connects up to eight drives either directly or through a port expander.
This configuration is mostly for low-end or entry servers. Enclosure
management is provided through out-of-band I
2
C bus. Side bands of
both types of internal SAS connectors support the SFF-8485
(SGPIO) interface.
Midrange internal SAS configurations: This is like the internal
SATA II configurations, but with high-end SAS drives. This is more
suitable for low-range to midrange servers.
High-end external SAS/SATA II configurations: This configuration
is for external connectivity using SATA II drives, SAS drives, or both.
External enclosure management is supported through in-band,
SCSI-enclosed storage. The configuration must support STP and
SMP.
Figure 1.1 shows a direct-connect configuration. The Inter-IC (I
2
C)
interface communicates with peripherals. The external memory bus
provides a 32-bit memory bus, parity checking, and chip select signals
for pipelined synchronous burst static random access memory
(PSBRAM), nonvolatile static random access memory (NVSRAM), and
Flash ROM.
Figure 1.1 Example of an LSI SAS Direct-Connect Application
Figure 1.2 shows an example of a SAS RAID controller configured with
an LSISASx12 expander that is connected to SAS drives, SATA II drives,
or both.
Flash ROM/
SAS
PCI Express
RAID Controller
SAS/SATA II Device
32-Bit Memory
Address/Data
Bus
PSBRAM/
I
2
C
SAS/SATA II Device
SAS/SATA II Device
SAS/SATA II Device
PCI Express Interface
NVSRAM
I
2
C
Interface