Installation guide
Chapter 2. CLI Syntax Reference
90 3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
3ware CLI> /c0 show
 Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
 ---------------------------------------------------------------------------
 u0 RAID-5 OK - - 64K 596.004 RiW OFF
 u2 SPARE OK - - - 149.042 - OFF
 u3 Migrator MIGRATING - 39 - 149.001 RiW OFF
 VPort Status Unit Size Blocks  Serial
 -----------------------------------------------------------------------
 p0 OK u0 149.05 GB 312581808 WD-WCANM1771318
 p1 OK u0 149.05 GB 312581808 WD-WCANM1757592
 p2 OK u0 149.05 GB 312581808 WD-WCANM1782201
 p3 OK u0 149.05 GB 312581808 WD-WCANM1753998
 p4 OK u2 149.05 GB 312581808 WD-WCANM1766952
 p5 OK u3 149.05 GB 312581808 WD-WCANM1882472
 p6 OK u0 149.05 GB 312581808 WD-WCANM1883862
 p7 OK u3 149.05 GB 312581808 WD-WCANM1778008
 p8 OK - 149.05 GB 312581808 WD-WCANM1770998
 p9 NOT-PRESENT - - - -
 p10 OK u3 149.05 GB 312581808 WD-WCANM1869003
 p11 OK u3 149.05 GB 312581808 WD-WCANM1762464
 3ware CLI> /c0/u3 show
 Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
 ------------------------------------------------------------------------
 u3 Migrator MIGRATING - 39 - - -
 su3 RAID-1 OK - - - - 149.001
 su3-0 DISK OK - - p5 - 149.001
 su3-1 DISK OK - - p7 - 149.001
 su3/v0 Volume - - - - - 149.001
 du3 RAID-10 OK - - - 16K 298.002
 du3-0 RAID-1 OK - - - - -
 du3-0-0 DISK OK - - p5 - 149.001
 du3-0-1 DISK OK - - p7 - 149.001
 du3-1 RAID-1 OK - - - - -
 du3-1-0 DISK OK - - p10 - 149.001
 du3-1-1 DISK OK - - p11 - 149.001
 du3/v0 Volume - - - - - 149.001
Example of migrate output for Single to RAID 1
The migration path from RAID type Single to RAID 1 is a special case. 
Because the single unit becomes a mirrored array, technically, this is not a 
migration. As a result, this command shows a different status than other 
migration paths. In addition, the status of the newly specified disk shows 
DEGRADED until the “migration/rebuild” is complete.
For example, below is a system with two migrating units, /c0/u0 and /c0/u1. 
Unit u0 is migrating from a RAID 10 to a RAID 0 unit, while unit u1 is 
migrating from Single to a RAID 1, initiated by the following commands:
 /c0/u0 migrate type=raid0
 /c0/u1 migrate type=raid1 disk=5