Installation guide
Chapter 2. CLI Syntax Reference
54 3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
stripe=size consists of the stripe size to be used. The following table 
illustrates the supported and applicable stripes on unit types. Stripe size units 
are in KB (kilobytes). If no stripe size is specified, 256K is used by default, if 
applicable. If you need to change the stripe size after the unit is created, you 
can do so by either migrating or recreating the unit. 
group=3|4|5|6|7|8|9|10|11|12/13|14|15|16 indicates the number of disks per 
group for a RAID 50 type. (You can use this attribute only when type=raid50.) 
Note that a RAID 50 is a multitier array. At the bottom-most layer, N number 
of disks per group are used to form the RAID 5 layer. These RAID 5 arrays 
are then integrated into a RAID 0. This attribute allows you to specify the 
number of disks in the RAID 5 level. Valid values are 3 through 16. However, 
no more than 4 RAID 5 subunits are allowed in a RAID 50 unit.
A sufficient number of disks are required for a given pattern or disk group. 
For example, given 6 disks, specifying 3 creates 2 RAID 5 arrays. With 12 
disks, specifying 3 creates 4 RAID 5 arrays under the RAID 0 level. With 
only 6 disks, a grouping of 6 is not allowed because you are basically creating 
a single RAID 5 unit.
The default RAID 50 grouping varies, based on number of disks. For 6 and 9 
disks, default grouping is 3. For 8 disks, the default grouping is 4. For 10 
disks, the default grouping is 5, and for 12 disks, the disks can be grouped into 
groups of 3, 4, or 6 drives (the group of 4 drives is set by default because it 
provides the best of net capacity and performance). For 15 disks, the disks can 
be grouped into 5 drives (3 drive groups would make 5 subunits; you can have 
a maximum of 4 subunits). For 16 disks, the disks can be grouped into groups 
of 4 or 8 drives.
noscan attribute instructs the CLI not to notify the operating system of the 
creation of the new unit. By default, the CLI informs the operating system.
nowrcache attribute instructs the CLI to disable the write cache on the newly 
created unit. By default, the write cache is enabled for best performance. If 
there is not a BBU or UPS installed, you can avoid the possibility of data loss 
in the event of a power loss, by setting nowrcache.
nordcache attribute instructs the CLI to disable the read cache on the newly 
created unit. Enabling the read cache increases performance. The 
rdcachebasic attribute instructs the CLI to set the read cache mode on the 
Table 6: Supported Stripe Sizes (KB)
 R0   R1   R5  R6  R10   R50  Single 
16 N/A 16 16 16 N/A
64 —64646464 —
256 — 256 256 256 256 —