Installation guide
Chapter 2. CLI Syntax Reference
40 3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
/cx show monitor
The /cx show monitor command shows the monitor (firmware boot-loader) 
version of controller /cx. 
Example:
 //localhost> /c0 show monitor
 /c0 Monitor Version = BLDR 2.x
/cx show numdrives
The /cx show numdrives command shows the number of drives currently 
managed by the specified controller /cx. This report does not include 
(logically) removed or exported drives. 
Example:
 //localhost> /c0 show numdrives
 /c0 Number of Drives = 5
/cx show numports
The /cx show numports command shows the total number of physical 
connections made to the controller and the maximum connections possible for 
the controller. 
Example for a 9650SE-16ML with no drives attached:
 //localhost> /c0 show numports
 /c0 Number of Ports = 16
Example for 9690SA-8E with 8 dual-port SAS drives:
 //localhost> /c3 show numports
 /c3 Connections = 16 of 128
/cx show numunits
The /cx show numunits command shows the number of units currently 
managed by the specified controller /cx. This report does not include off-line 
units (or removed units). 
Example:
 //localhost> /c0 show numunits
 /c0 Number of Units = 1
/cx show pcb
The /cx show pcb command shows the Printed Circuit Board (PCB) version 
of the specified controller /cx. 
Example:
 //localhost> /c0 show pcb
 /c0 PCB Version = RevX