Installation guide
Command Logging
www.lsi.com/channel/products  127
help /c
x
/e
x
/temp
x
help /cx/ex/tempx command provides specific temperature sensor cx/ex/
tempx-related help, illustrating various ways to use the cx/ex/tempx 
command. See the section “Enclosure Object and Element Commands” on 
page 109 for more information.
help /c
x
/e
x
/pwrs
x
help /cx/ex/pwrsx command provides specific power supply /cx/ex/pwrsx-
related help, illustrating various ways to use the /cx/ex/pwrsx command. See 
the section “Enclosure Object and Element Commands” on page 109 for more 
information. 
help /c
x
/e
x
/alm
x
help /cx/ex/almx command provides specific enclosure alarm /cx/ex/almx-
related help, illustrating various ways to use the /cx/ex/almx command. See 
the section “Enclosure Object and Element Commands” on page 109 for more 
information.
Command Logging
Both the CLI and 3DM2 have a logging function that makes an entry into a 
log file for each command line that makes a change to the controller 
configuration (for example, add/delete units). 
This logging function is enabled by default for CLI. It can be turned on for 
3DM2, through the 3DM2 web interface. 
You might be asked to supply this log file to the LSI technical support team 
for troubleshooting.
Location of the Log File
The log file name is tw_mgmt.log. 
For Windows Vista, Server 2008, and Windows 7
The log file is stored in 
\ProgramData\3ware
Note that ProgramData is a hidden folder by default. To show it in Windows 
Explorer, type 
c:\ProgramData in the location field at the top of the Explorer 