Enclosure Object and Element Commands
www.lsi.com/channel/products  121
Example:
 //localhost> /c0/e0/alm0 set alarm=unmute
 Setting alarm audibility setting of /c0/e0/alm0 to [unmute] ... 
Done.
/cx/ex update fw=filename_with_path [sep=n] 
[force]
The /cx/ex update command applies only to 9750 controllers.
The /cx/ex update command downloads the specified expander firmware 
image to the target SEP (Storage Enclosure Processor) expander that supports 
the SES-2 (SCSI Enclosure Services) standard for enclosure management. 
(CCU enclosures with SAF-TE protocol are not supported.) 
For details about working with this command, see the LSI 3ware 
KnowledgeBase. Go to http://kb.lsi.com and refer to article # 15803.
/cx/ex show firmware 
The /cx/ex show firmware command lists the SEP and corresponding 
firmware version in the specified expander. This command applies only to 
9750 controllers.
Example:
//localhost > /c1/e0 show firmware
/c1/e0 SEP=0, Firmware Version = 90.00.03.15
Note: Some enclosures support alarms but not the mute/unmute function. For 
these enclosures, using this command to set the alarm to 
mute returns an error 
message indicating that the feature is not supported. For these enclosures, the 
alarm is not mutable; however, it can be turned 
off. 
If you set this command to 
unmute for an enclosure that does not support mute, 
the command appear to complete and does not report an error. However in this 
case, there is no mute setting to change to unmute. 