Installation guide
Enclosure Object and Element Commands
www.lsi.com/channel/products  119
/cx/ex/tempx show
The /cx/ex/tempx show command applies only to 9750 and 9690SA 
controllers. For the 9650SE, simply drop the prepended controller name in the 
command and use /ex.
The /cx/ex/tempx show command shows the information about the specified 
temperature sensor element /tempx in the specified enclosure cx/ex. The 
possible status values are OK, OVER-WARNING, OVER-FAIL, UNDER-
WARNING, UNDER-FAIL, where OVER denotes over-temperature and 
UNDER denotes under-temperature. For more information about these 
statuses, see “Temp Sensor Status” in the 3ware SATA+SAS RAID Controller 
Card Software User Guide, Version 10.2. 
Example:
 //localhost> /c0/e0/temp0 show 
 TempSensor Status Temperature Identify
 --------------------------------------------------------
 temp0 OK 42C(107F) Off
/cx/ex/tempx show identify
The /cx/ex/tempx show identify command applies only to 9750 and 9690SA 
controllers. For the 9650SE and CCU enclosure, simply drop the prepended 
controller name in the command and use /ex.
The /cx/ex/tempx show identify command shows the identify status of the 
specified temp sensor. The status can be either on or off. If identify is on, the 
LED associated with the temp sensor blinks. If the enclosure does not support 
Temperature Sensor Identify, this command returns N/A.
Example:
 //localhost> /c0/e0/temp1 show identify
 /c0/e0/temp1 Identify status = on
/cx/ex/tempx set identify=on|off
The /cx/ex/tempx set identify command applies only to 9750 and 9690SA 
controllers. For the 9650SE, simply drop the prepended controller name in the 
command and use /ex.
If the enclosure supports Temperature Sensor Identify, this command causes 
the LED associated with the temp sensor to blink, or turns off identification of 
the LED for this temp sensor. 
Example:
 //localhost> /c0/e0/temp1 set identify=on
 Setting Temperature Sensor Identify on /c0/e0/temp1 to [on] ... 
Done.