Installation guide
Enclosure Object and Element Commands
www.lsi.com/channel/products  113
2 - Low
3 - Medium-low
4 - Medium
5 - Medium-high
6 - High
7 - Highest
The Identify column lists the Identify setting of the fans.
Example:
 //localhost> /c0/e0 show fans
  ---Speed---
 Fan Status State  Step RPM Identify
 ------------------------------------------------------------
 fan0 OK ON  1 2670 Off
 fan1 OK ON  1 9370 Off
 fan2 OK ON  1 8540 Off
 fan3 OK ON  1 2810 Off
 fan4 OK ON  1 9240 Off
 fan5 OK ON  1 8330 Off
/cx/ex show temp
The /cx/ex show temp command applies only to 9750 and 9690SA 
controllers. For the 9650SE, simply drop the prepended controller name in the 
command and use /ex. 
The /cx/ex show temp command lists the temperature sensors in enclosure 
/cx/ex and the current temperature.
The maximum temperature for successful use of a drive should be noted in the 
documentation for the drive. 
The TempSensor column lists the temperature sensor IDs, the Status column 
lists the status of each temperature sensor, the Temperature column lists the 
temperature at the sensors, and the Identify column lists the Identify setting of 
the temperature sensors
Example:
 //localhost> /c0/e0 show temp
 TempSensor Status Temperature Identify
 --------------------------------------------------------
 temp0 OK 41C(105F) Off
 temp1 OK 37C(98F) Off
 temp2 OK 34C(93F) Off
 temp3 OK 38C(100F) Off
 temp4 OK 38C(100F) Off
 temp5 OK 34C(93F) Off
 temp6 NOT-INSTALLED -  Off
 temp7 NOT-INSTALLED -  Off