Installation guide
BBU Object Commands
www.lsi.com/channel/products  107
/cx/bbu show temp
The /cx/bbu show temp command shows the temperature status of the 
battery. The status can be OK, HIGH, LOW, TOO-HIGH, and TOO-LOW. 
The HIGH and LOW are in warning range. TOO-HIGH and TOO-LOW are 
out of the operating range and indicate the need to replace the battery. 
(Contact LSI to obtain a replacement battery.)
This command is equivalent to the command /cx/bbu show tempstat.
Example:
//localhost> /c0/bbu show temp
 /c0/bbu Battery Temperature Status = OK
/cx/bbu show tempstat
This command is equivalent to the command /cx/bbu show temp. 
/cx/bbu show tempval
The /cx/bbu show tempval command shows the temperature of the BBU in 
Celsius. 
Example:
//localhost> /c0/bbu show tempval
 /c0/bbu Battery Temperature Value = 24 deg C
/cx/bbu show volt
The /cx/bbu show volt command shows the voltage status of the battery. The 
status can be OK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and 
LOW are in warning range. TOO-HIGH and TOO-LOW are out of the 
operating range and indicate the need to replace the battery. (Contact LSI to 
obtain a replacement battery.) 
/cx/bbu show all
The /cx/bbu show all command shows the current settings of all BBU-related 
attributes: ready, status, batinst, lasttest, volt, temp, cap, serial, fw, pcb, 
bootloader. 
Example:
 //localhost> /c1/bbu show all
/c1/bbu Firmware Version = BBU: 2.00.00.023
/c1/bbu Serial Number = L319003B7460719
/c1/bbu BBU Ready = Yes
/c1/bbu BBU Status = OK
/c1/bbu Battery Voltage = OK