Installation guide
BBU Object Commands
www.lsi.com/channel/products  103
Supported, Enabled, and Control. The Supported and Enabled values are set 
for the phy and are not changeable. The Control value is the link speed that 
can be set with the /cx/phyx set link=auto|1.5|3.0|6.0 command. The default 
is auto. 
Example:
 //localhost> /c3/phy0 show
 Device --- Link Speed (Gbps) ---
 Phy SAS Address Type Device Supported  Enabled Control
 --------------------------------------------------------------------------
 phy0 2007020800153811 SATA /c3/p1 1.5-3.0  3.0 1.5
/cx/phyx set link=auto|1.5|3.0|6.0
The /cx/phyx set link command sets the link speed for the specified phy. This 
controls the speed between the controller and the hard drive or enclosure to 
which it is connected. The possible values for SAS and SATA drives are: 
auto, 1.5, 3.0, or 6.0. Speed is in gigabits per second and the default 
setting is auto.
Example:
//localhost> /c0/phy0 set link=1.5
 Sending link speed control of /c0/phy0 to [1.5 Gbps] ... Done.
BBU Object Commands
Battery Backup Unit (BBU) Object Commands are commands that provide 
information and perform actions related to a specific BBU installed on a 
specific controller, such as /c0/bbu.
This object is only available on controllers on which a BBU is actually 
installed. 
Syntax
/cx/bbu show 
Note: After link speed control is set to a different value, you must reboot the system 
for the new link speed to take effect. 
Note: The BBU firmware version and bootloader version do not apply for 9750 
controller models. 