Installation Guide
CONDITION
Snug
Flush
Visible Fiber
Countersunk
1/16 - 1/8 inch
Countersunk 
more than 1/8 inch
CORRECTION
OK
OK
Paint
Apply Sealant
Apply Sealant and
re-nail
TRIM & FASCIA           190, 440, 540 & 2000 SERIES
• Fasteners:  6d (0.099”) or 8d (0.113”) 
non-staining, hot-dipped galvanized 
(ASTM A-153) or equal. Apply and correct 
overdriven nails as shown in Table 3a.
• Sealant:  Use an exterior-quality, 
non-hardening, paintable sealant. Use 
Class 25 or higher exterior sealant meeting 
the ASTM C920 Standard for Specication 
for Elastomeric Joint Sealants. Follow the 
sealant manufacturer’s instructions for 
application.
• Paint:  Exterior-quality 100% acrylic latex 
paint, specially formulated for use on wood 
and engineered wood substrates, is highly 
recommended. Semi-gloss or satin nish 
oil or alkyd paints are acceptable. For at 
alkyd  paint,  please  check  with  the  coating 
manufacturer for their recommendations for 
use on composite wood siding.
GENERAL REQUIREMENTS (CONTINUED)
• Framing: A maximum of 24 inch o.c. intermediate support 
is required for sot greater than 12 inches wide. 24 inch o.c. 
intermediate support is NOT required for sot 12 inches wide 
and under. (See diagrams 4a and 4c) 
• Framing shall be of sucient size and quality to securely attach 
the sot. Installer is resposible for ensuring all framing meets 
local building code requirements.
• All panel ends and edges must be supported or backed by 
solid support. Additional blocking may need to be installed. 
Complete perimeter framing support is required for all sot. 
• Panels must be installed perpendicular to framing supports, 
except in open sot applications over gabled eaves.
• Fastener length: Long enough to fully penetrate framing 
support a minimum of 1 inch. (See diagram 3b)
• Fastener placement: 3/8 inch from ends and edges.
• Fastener spacing: Space nails a maximum of every 6 inches 
o.c. at panel edges and a maximum of every 12 inches o.c. along 
intermediate supports. (See diagrams 4b and 4d) 
Table 3a
3b
PREPARATION
General Application Equipment
End Joint
GENERAL REQUIREMENTS (CONTINUED)
INSTALLATION
Standard Fastening Instructions
1” min.
Space 3/16” and 
apply sealant
LP SmartSide CTW, Vented CTW and Sot Panels
(Long Dimension Across Supports)
 Maximum Span (inches)
All Edges Supported
24
24
24
Product Category
38 Series Strand 
Substrate
76 Series Strand & Fiber 
Substrate
190 Series Strand 
Substrate
Minimum Nail Size
and Type
6d (0.099") 
hot-dipped 
galvanized
 or equal
8d (0.113") hot-dipped 
galvanized
 or equal
8d (0.113”) hot-dipped 
galvanized
 or equal
LP SmartSide Sot
3
• For information on fastening LP SmartSide sots in high wind areas, 
 refer to APA Product Report PR-N117 found at www.lpcorp.com.