Pub. 988-0151-182 Addendum I LMS-480M, LMS-480DF & GlobalMap® 4800M This addendum addresses new items packed with your unit, changes to installation procedures, and NMEA 2000 ® upgrades not documented in the LMS 480M, LMS-480cDF and GlobalMap 4800M manuals. Your unit now packs with a 2-foot (61 cm) blue-to-red adapter cable, 15foot (4.6 m) extension cable, LGC-3000 GPS module, double T connector and two 120-ohm terminators.
Power Connections Your unit comes with a power/data cable that splits into three branches, each with several exposed wires. The thicker three-wire cable (white, red and black) is the power supply for your display unit. This cable has no label. The thinner branch with three wires (red, black and shield) is the power cable for a NMEA 2000 network. It is labeled "NMEA 2000 POWER." The branch with four wires (blue, yellow, orange, and shield) is a data cable, labeled "RS-232 COMM.
Powering Your Display Unit The display unit works from a 12-volt DC battery system. Attach the display power cable (with provided 3-amp fuse) to an accessory switch or power bus. If this results in electrical interference, connect direct to a battery but install an in-line switch on the cable. Caution: We strongly recommend that you shut off the power supply to the power cable when the unit is not in use, especially in saltwater environments.
For example, if you have to extend the power cable to the power bus or battery, attach one end of the fuse holder directly to the power bus or battery. This will protect both the unit and the power cable in the event of a short. This unit has reverse polarity protection. No damage will occur if the power wires are reversed. However, the unit will not work until the wires are attached correctly.
Powering a NMEA 2000 Network Bus A NMEA 2000 bus must be connected to a power source to operate. NMEA 2000 devices, including GPS modules, draw their power from the network bus. If you have a pre-existing NMEA 2000 network installation, it may already be connected to another power source. If you are not sure about a network's power status, consult the boat manufacturer or dealer. If your NMEA 2000 bus is already powered, you can ignore the NMEA 2000 Power cable and use the method shown in Power Diagram B.
when not in use. Failure to connect to and use a power switch will drain your boat battery, which could stop your boat's operation. GPS Antenna/Receiver Module Your unit packs with the LGC-3000 GPS module. This device contains the unit's external antenna and receiver for GPS and WAAS signals. The antenna/receiver module comes with a 15-foot (4.6 m) extension cable. This module can be mounted on a flat surface or pole, or an optional magnet is available for temporary mounting on any ferrous surface.
the telephone wiring in a house. If you pick up a phone in your living room, you can hear someone talking into the phone in the bedroom. Lowrance and LEI provide all the cables you will need to create a NMEA 2000 network. Lowrance provides T connectors and extension cables so you can add devices along the backbone wherever you want. Once you have a working network, every sensor added will come with its own T connector for easy expansion.
Network socket Sonar socket Power/Data socket 120 ohm terminator 120 ohm terminator Speed sensor Double T connector Display unit power cable Data cable NMEA-2000 Power cable Blue-to-red adapter cable Extension cable Transducer LGC-3000 Cable connections for LMS-480M and LMS-480DF.
Network socket 120 ohm terminator Power/Data socket 120 ohm terminator Double T connector Extension cable Display unit Data power cable cable NMEA-2000 Blue-to-red Power cable adapter cable LGC-3000 Cable connections for the GlobalMap 4800M.
NMEA 2000 Device Configuration The NMEA 2000 menu on your display unit's main menu allows you to configure, calibrate and monitor devices on a NMEA 2000 network. The NMEA 2000 menu provides access to the Bus Setup, Fuel Management and NMEA 2000 Alarms. You also can turn on/off Waypoint Sharing and Backlight Synchronization from the NMEA 2000 menu. NOTE: The menus in your unit may differ slightly from the screen captures used in this document.
The NMEA Diagnostics page displays information about the performance of the network bus, keeping you updated on bus status, mode, errors and bus traffic. The Ethernet Diagnostics page keeps you updated on the performance of an Ethernet connection (if applicable) supplying information ranging from IP Address to upload and download rates (bytes per second). To refresh either Diagnostics page, highlight the PING ALL DEVICES button at the bottom of the page and press ENT.
Tank Select The Tank Select menu allows you to choose from up to three tanks (Port, Center and Starboard), depending on the Engine-tank configuration that has been selected. This allows you to set up each tank individually. Tank Size The Tank Size menu allows you to input the size of a selected tank in gallons. After selecting the desired tank from the Tank Select menu, you are ready to enter the tank's size.
7. Use ↓ ↑, ← → to input the capacity (gallons) of the tank you chose from the Tank Select menu and press ENT. 8. Repeat Steps 5-7 for each remaining tank. 9. When all tanks have been configured, press the SET CONFIGURATION button. The following confirmation message will appear: Are you sure you wish to change the bus configuration? Choose YES and press ENT, Press EXIT to get back to the main display.
The Device Data for an EP-10 Fuel Flow includes Fuel Rate (amount of fuel burned per hour), Fuel Used, Trip Fuel Used and Seasonal Fuel Used. NOTE: If, as in the graphic above, you do not have a Suzuki Engine Interface, EP-15 Fluid Level or EP-10 Fuel Flow on the network, the Engine & Configuration menu, Tank Select menu, Tank Size dialog and Set Configuration button will not be displayed on the Bus Configuration menu.
Add Fuel After entering the amount of fuel added to a tank in the Fuel Added dialog, the Add Fuel command finalizes the entry of the data. Like the Fuel Added dialog, the Add Fuel command will only be used when an amount of fuel is added that does not fill up the tank. Fill Tank You will use the Fill Tank command when calibrating a fuel flow and when filling up the tank without calibration.
To Reset Calibration: Choosing the Reset Calibration command will switch fuel flow calibration settings back to factory defaults. 1. Press MENU|MENU, select NMEA 2000 and press ENT. 2. Highlight FUEL MANAGEMENT and press ENT. The Fuel Management menu will appear. 3. Highlight to ENGINE SELECT and press ENT. Select the desired engine — the engine attached to the desired fuel flow — and press ENT. 4. Highlight RESET CALIBRATION and press ENT.
The second tab at the top of the NMEA 2000 Alarms page is the Alarm Status Tab. When an alarm has been set for a device, the alarm and its current status will be shown on the Alarm Status window. To view the Alarm Status window, highlight the Alarm Status tab and press ENT. To set NMEA 2000 Alarm: 1. Press MENU|MENU, select NMEA 2000 and press ENT. 2. Highlight NMEA 2000 ALARMS and press ENT. 3. Highlight FLUID LEVEL DEVICE and press ENT.
Configuring EP Sensors All configurable devices are configured through their Device Configuration menus, which may be accessed through the network devices list on the Bus Configuration menu. EP-35 Temperature Configuration To input Device Name: 1. Press MENU|MENU, use ↑ ↓ to select NMEA 2000 and press ENT. The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. 2.
Instance The Instance command is intended for use only by experienced NMEA 2000 network technicians. Instance allows network technicians to resolve certain electronic probe conflicts. This is most likely to occur if the network includes LMF-200 or LMF-400 digital gauges, which support the display of fewer electronic probes than your GPS or sonar/GPS unit. If you want to use your unit in a network including one of these digital gauges, you may need to consult customer service.
3. Select the fuel flow you want to rename and press ENT. The Device Configuration menu will appear with the Device Name dialog box highlighted. 4. Press ENTER and use ↑ ↓, ← → to input the desired name for the fuel flow. Press ENT. Press EXIT repeatedly to get back to the main display. To select a Location: 1. Press MENU| MENU, use ↑ ↓ to select NMEA 2000 and press ENT.
To restore default settings: 1. Press MENU| MENU, use ↑ ↓ to select NMEA 2000 and press ENT. The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. 2. Highlight BUS SETUP and press ENT, which will open the Bus Configuration menu. A list of network devices will be at the top of the page. 3. Use ↑ ↓ to select the desired fuel flow and press ENT. The Device Configuration menu will appear. 4.
5. Select the desired Tank Instance (location) and press ENT. The following confirmation message will appear: Are you sure you wish to change this device's configuration? 6. Highlight YES and press ENT. Press EXIT repeatedly to get back to the main display. To select Fluid Type: 1. Press MENU| MENU, use ↑ ↓ to select NMEA 2000 and press ENT. The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. 2.
Instance The Instance command is intended for use only by experienced NMEA 2000 network technicians. Instance allows network technicians to resolve certain electronic probe conflicts. This is most likely to occur if the network includes LMF-200 or LMF-400 digital gauges, which support the display of fewer electronic probes than your GPS or sonar/GPS unit. If you want to use your unit in a network including one of these digital gauges, you may need to consult customer service.
Suzuki Engine Interface Configuration To input Device Name: 1. Press MENU| MENU, use ↑ ↓ to select NMEA 2000 and press ENT. The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. 2. Highlight BUS SETUP and press ENT, which will open the Bus Configuration menu. A list of network devices will be at the top of the page. 3. Use ↑ ↓ to select the engine interface you want to rename and press ENT.
5. Select your engine type and press ENT. The following message will appear: Are you sure you wish to change this device's configuration? 6. Highlight YES and press ENT. Press EXIT repeatedly to get back to the main display. Advanced Options menu The Engine Interface Advanced Options menu contains three categories: Instance, Restore Defaults and Reset Trim Calibration. Instance The Instance command is intended for use only by experienced NMEA 2000 network technicians.
NOTE: The Suzuki Engine Interface Device Configuration menu contains two Engine Trim calibration commands, which will be addressed in the next segment of this section, Calibrating EP Sensors. Calibrating EP Sensors The factory calibration settings for the EP-10 Fuel Flow, EP-15 Fluid Level and Suzuki Engine Interface should be adequate for the majority of applications, so calibration will not be necessary in most cases.
To calibrate an EP-10 Fuel Flow: 10. If calibration is necessary, press MENU|MENU, select NMEA 2000 and press ENT. 11. Highlight FUEL MANAGEMENT and press ENT. 12. Select TANK LOCATION and press ENT to choose the location of the tank connected to selected fuel flow. Press ENT. 13. Highlight FILL TANK and press ENT. The following message will appear: Are you sure you wish to Fill Tank? Select YES and press ENT. 14.
3. Select the EP-15 Fluid Level and press ENT. 4. Press ↓ to select CALIBRATE and press ENT. The Device Calibration menu will appear. Instructions on Calibration will be listed at the top of the menu. 5. Highlight NUM PTS, press ENT and select 2. Press ENT. 6. Select FLUID LEVEL, press ENT, then select EMPTY LEVEL and press ENT. Calibrate is highlighted on the device configuration menu (left). Calibration menu (right) with calibration instructions listed at the top. 7.
4. Press ↓ to select CALIBRATE and press ENT. The Device Calibration menu will appear. 5. Highlight NUM PTS, press ENT and select 3. Press ENT. 6. Make sure your tank is empty, then highlight FLUID LEVEL and press ENT. Select EMPTY LEVEL and press ENT. 7. Select CALIBRATE and press ENT. The following message will appear: Empty Level Calibration Completed. Press ENTER. 8. Add half a tank of fuel, highlight FLUID LEVEL and press ENT. Select HALF LEVEL and press ENT.
1. Press MENU| MENU, use ↓ ↑ to select NMEA 2000 and press ENT. 2. Highlight BUS SETUP and press ENT, which will open the Bus Configuration menu. A list of network devices will be at the top of the page. 3. Select the desired EP-15 Fluid Level and press ENT. 4. Press ↓ to select CALIBRATE and press ENT. The Device Calibration menu will appear. 5. Highlight NUM PTS, press ENT and select 5. Press ENT. 6. Make sure your tank is empty, then highlight FLUID LEVEL and press ENT. Select EMPTY LEVEL and press ENT.
1. After selecting Fuel Used as overlay data, fill up your tank and press MENU|MENU. 2. Select NMEA 2000 and press ENT. 3. Highlight FUEL MANAGEMENT and press ENT. Select TANK LOCATION and press ENT. 4. Use ↑ ↓ to select the location (Port, Center or Starboard) of the engine interface you want to calibrate and press ENT. 5. Highlight FILL TANK and press ENT. The following confirmation message will appear: Are you sure you wish to Fill Tank? 6. Select YES and press ENTER.
3. Highlight CALIBRATE TRIM and press ENT. The Device Calibration window will appear with a list of Calibration Instructions. 4. Highlight START CALIBRATION and press ENT. The following message will appear: Please fully raise the Engine Trim. 5. After engine trim has been fully raised, press ENT. The following message will appear: Please fully lower the Engine trim. 6. After engine trim has been fully lowered, press ENT. A Calibration Completed message will appear. Press ENT. 7.
Reset Calibration highlighted (left). Reset Calibration confirmation window (right). To Reset Calibration: 1. Press MENU|MENU, select NMEA 2000 and press ENT. 2. Highlight FUEL MANAGEMENT and press ENT. 3. Highlight ENGINE SELECT and press ENT. The Engine Select menu will appear with up to four options: All Engines, Port, Center and Starboard. Selecting All Engines will reset calibration for all engines back to factory defaults. 4.
Notes 34
Notes 35
Visit our web site: Lowrance Pub. 988-0151-182 © Copyright 2006 All Rights Reserved Lowrance Electronics, Inc.