Manual
Table Of Contents
PAGE18 of 28
PARALLELING TWO DG-12II’s:
Two DG-12 units can be paralleled so that a zone can be
monitored and controlled from two different locations. See fig. 13
for interconnection diagram between two DG-12II’s and DG-MA.
See Fig. 14 for interconnecting the two plug-in connectors of two
DG-12II’s. Note that only one DG-12II gives power to the
remote microphone as shown by two end cables not connected.
The plug-in connector on the left hand side is the one giving
power to the remote station. No cable is connected to the “A”
terminal of the other connector. These plug-in connectors plug
into the Mic/Talkback 5-Pin Header[24] at the rear panel of the
respective DG-12II.
II
Fig. 13 Paralleling two DG-12II’s
Fig 14 Paralleling two plug-in connectors of two DG-12II’s
INPUT
AUDIO
OUTPUT
1 2
3
4
5
ZONE 9
ZONE 10
ZONE 7
ZONE 8
ZONE 9
ZONE 10
ZONE 7
ZONE 9
“A” terminal not used
at second DG-12II
DG-MA
A
B
C
SP
G
A
B
C
SP
G
DG12II #2
DG12II #1
LOUROE ELECTRONICS 6955 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
Website: www.louroe.com Email: sales@louroe.com
(818)
INSTALLATION AND OPERATING INSTRUCTIONS
DG-12II 2/08