User's Manual
Guide to the SRX800 Receiver Preliminary
1)CO N F I G ## > 5)FI L T E R S
Received signals can be qualified for storage and display by using a set of filters.
This section of the manual describes two filter classes, one pertaining to signals
(frequency/channel and transmitter ID) and the other to signal quality (signal
strength and pulse timing).
ID FI L T E R
Filtering provides the ability to filter Channel plus ID combinations or IDs only
without altering a configuration’s frequency table. IDs or Channel plus ID
combinations can be accepted or rejected by creating accept or reject lists. Each
accept or reject list can have up to 100 entries.
Four types of filters are available, but only one filter type can be selected at a
time. Once a filter type is selected, the receiver uses the list created for that filter
type to apply the settings.
SE T T I N G T H E FI L T E R TY P E
Only one filter type can be selected at a time. Select the filter type via:
Codelog > 1)Config > 5)Filters > 1)ID Filter
Four choices are available:
1)No Filter, 2)Reject Ch/ID, 3)Accept Ch/ID, 4)Reject ID 5)Accept ID
NO FI L T E R
If no filtering is desired, select 1)No Filter.
RE J E C T I N G CH A N N E L P L U S ID
Use this feature to create a list of Channel plus ID combinations that will be
rejected during a scan. All Channel plus ID combinations added to this list are