User's Manual

LO G G I N G O N T O T H E R E C E I V E R
Logging on to the receiver provides the ability to change the state of the receiver.
When a log on password is provided the receiver is considered Online. If no
password is provided (logged off) then the receiver is Offline. The differences
between Online and Offline are described below:
Offline: the receiver allows read-only access, which means that most inputs
are not allowed (unless a log on password is provided). The only allowed
input is the Reset Password function.
Online: the receiver allows full write access, which means that all
functionality and input capabilities are available.
Log on to the receiver via:
Log On > 1)Log On or Log On > 2)Log On via Factory Password.
Wait a few seconds for the changes to be accepted and then the receiver returns
to the last state that was active (e.g. scan) or the start page.
The log on password is always “123456” unless it is changed via Setup >
3)Change Password.
Logging on via the factory password allows you to log on quickly, provided the
factory password (“123456”) is being used. This feature is convenient if you do
not need or want to have a specific confidential password.
Logging on can be done at any time during operation of the receiver, except
while using the Info key and its menu items.
LO G G I N G OF F
Logging off can be done at any time during operation of the receiver. Data
collection can continue while limiting access to settings via a password. Logging
off means the receiver is Offline.
Log off from the receiver via: