User's Manual

Rev B
8
or, in versions supporting individual antenna or channel gains,
(where XX is the current value) and then waits until it receives two numeric inputs from the
keypad. Shifted or non-numeric keys (except
ESC) are ignored. The system gain is then set
according to the received two-digit value. Pressing the
ESC (escape) key causes the function to
abort without updating. On exit, the command display (frequency and gain) is restored.
The
UPARROW key is used to increment the value of a selected variable (normally
frequency, gain or scan time) by a selected amount. The variable is selected by
whichever of the
SET G, SET F, or SET SCAN keys were most recently activated. The
increment amount is the last value entered using the
SET function. The UPARROW is also used to
confirm real number entries (e.g., sensor calibration values). See also the discussion of the arrow
keys in the
SCAN mode.
The
SET F key activates a function which permits programming of the receiver operating
frequency.
SET F first issues a prompt:
and then waits until it receives input from the keypad in the form of a 6-digit decimal number (5
digits in 30 - 70 MHz versions) representing the receive frequency in MHz (megahertz). It then
sets the receive frequency by programming the frequency synthesizer. If the requested frequency
is out of range of the hardware it may, depending on the receiver configuration, be automatically
limited to a minimum or maximum value. Pressing the
ESC (escape) key causes the function to
abort without updating. On exit, the command display (frequency and gain) is restored.
The
SET SCAN key sets the dwell time for the SCAN and SEARCH functions. It issues a
prompt:
and then waits until it receives five numeric inputs (0 to 9) which it automatically formats as
X:XX.XX (minutes:seconds.hundredths). Shifted or non-numeric keys (except
ESC) are ignored.
The scan time is then set according to the received five-digit value. Pressing the
ESC (escape) key
causes the function to abort without updating. On exit, the command display (frequency and
gain) is restored, with the scan time now appearing in the lower left quadrant.
ENTER GAIN (00-99)
>
MASTER GAIN (XX)
>
SET F
ENTER FREQUENCY
>
SET SCAN
9
ENTER SCAN TIME
>