User's Manual
Page 4 Lotek Biotracker Receiver User’s Manual
Quick Start Guide
Before first use, we recommend you put the Biotracker on charge. The battery is fully-
charged when the receiver is manufactured, but rechargeable batteries self-discharge
slowly over time and after any period of storage will not be at full capacity.
Description of receiver operation
The receiver has three modes: Frequency, Channel and Scan.
Frequency Mode: Frequency is set directly via the numeric keypad or arrow keys.
Channel Mode: Channels holding stored frequencies are selected via the numeric
keypad or arrow keys. There are 256 channels.
Scan Mode: The receiver steps in numerical sequence through all channels or
selected channels only.
Basic Functions
• To turn the receiver on and off hold [ON/OFF] down for at least a second.
• To toggle between Frequency and Channel Mode (shown by ‘F’ or ‘C’ in bottom right
corner of display) press [F/C].
• [X] cancels the current operation.
• [
] enters the current number (channel, frequency etc) or completes the current
operation.
• [DEL] deletes the character at current cursor position. To delete the contents of a
channel in Channel Mode hold the button down for more than a second.
• The key with the light bulb symbol toggles the display back-light on and off. The light
switches off automatically after about 4 minutes.
• To adjust receiver gain, use the keys with loudspeaker symbols. The gain level (00 to
99) is displayed next to the mode indicator on the bottom row of the LCD. Gain can
also be adjusted (up to the limit shown in the display) using the gain knob. The knob
does not change the gain level displayed on the LCD.
• Signal strength is displayed on the top line of the LCD as a horizontal bar graph, and
the peak signal value is displayed on the top right. The peak value is held on the
display for 1 second or updated if another signal is received sooner.
Frequency Mode
• In Frequency Mode ‘F’ is displayed in the bottom right corner of the display.
• Typing a number enters the kHz frequency units (numbers after the decimal point).
Press [
] to set the frequency or [X] to cancel and revert back to the previous
frequency.
• To change the MHz frequency (numbers before the decimal point) press [MHz].
Enter the MHz frequency and press [
] to set or [X] to cancel.
• The up/down arrows tune the frequency one step at a time, at the current tuning
resolution (1 kHz or 0.1 kHz).
• The tuning resolution is toggled between 1 kHz and 0.1 kHz by the key
marked [.000 / .0000].
Channel Mode
• In Channel Mode ‘C’ is displayed in bottom right corner of display.
• The up/down arrows step through stored channels in the receiver’s memory.
• Channels can also be recalled by entering a channel number. Press [
] to set
or [X] to cancel.
• To delete the contents of a channel, press [DEL] for a second or more.