SDS
                                                                                Safety Data Sheets (SDSs) 
Report No.: ZRLK1506060007                                                                                             Page 6 of 10 
Conditions for safe storage, including any incompatibilities 
If the Lithium button cell is subject to storage for such a long term as more than 3 months, it is recommended 
to recharge the Lithium button cell    periodically. 
3 months: -10℃~+40℃, 45 to 85%RH 
And recommended at 0℃~+35℃ for long period storage. 
Do not storage Lithium button cell haphazardly in a box or drawer where they may short-circuit each other or 
be short-circuited by other metal objects. 
Keep out of reach of children. 
Do not expose Lithium button cell to heat or fire. Avoid storage in direct sunlight. 
Do not store together with oxidizing and acidic materials. 
Keep ignition sources away- Do not smoke. 
Store in cool, dry and well-ventilated place.   
Incompatible Products  None known. 
8.  EXPOSURE CONTROLS AND PERSONAL PROTECTION 
Control parameters 
CAS Number 
ACGIH 
NIOSH 
OSHA 
7782-42-5 
TLV-TWA 2mg/m
3
RELs-TWA2.5mg/m
3
PELs-TWA 15mppcf 
1333-86-4 
TLV-TWA 3mg/m
3
RELs-TWA3.5mg/m
3
PELs-TWA 3.5mg/m
3
108-32-7 
TLV-TWA 2ppm 
RELs-TWA3.5mg/m
3
PELs-TWA 240mg/m
3
1313-13-9 
PELs-TWA 0.1mg/m
3 
PELs-TWA 0.02mg/m
3
N/A 
N/A 
Other Exposure Guidelines  Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. 
OSHA, 965 F.2d 962(11th Cir., 1992). 
Appropriate engineering controls 
Engineering Measures  Showers   
Eyewash stations 
Ventilation systems 
Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible 
exposure limits. Ensure adequate ventilation. 
Individual protection measures, such as personal protective equipment 
Eye/Face Protection: 
Tightly sealed goggles 
Body protection: 
Protective work clothing. 
Skin protection: 