SDS
Safety Data Sheets (SDSs)
Page 6 of 10
Conditions for safe stor age, including any incompatibilities
If the Lithium Manganese Dioxide Button Cell is subject to storage for such a long term as more than 3
months, it is recommended to recharge the Lithium Manganese Dioxide Button Cell periodically.
3 months: -10℃~+40℃, 45 to 85%RH
And recommended at 0℃~+35℃ for long period storage.
Do not storage Lithium Manganese Dioxide Button Cell haphazardly in a box or drawer where they may
short-circuit each other or be short-circuited by other metal objects.
Keep out of reach of children.
Do not expose Lithium Manganese Dioxide Button Cell to heat or fire. Avoid storage in direct sunlight.
Do not store together with oxidizing and acidic materials.
Keep ignition sources away- Do not smoke.
Store in cool, dry and well-ventilated place.
Incompatible Pr oducts None known.
8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
Control parameters
CAS Number
ACGIH
NIOSH
OSHA
7782-42-5
TLV-TWA 2mg/m
3
RELs-TWA2.5mg/m
3
PELs-TWA 15mppcf
1333-86-4
TLV-TWA 3mg/m
3
RELs-TWA3.5mg/m
3
PELs-TWA 3.5mg/m
3
1313-13-9
PELs-TWA 0.1mg/m
3
PELs-TWA 0.02mg/m
3
N/A
N/A
Other Exposur e Guidelines Vacated limits revoked by the Court of Appeals decision in AFL-CIO v.
OSHA, 965 F.2d 962(11th Cir., 1992).
Appr opriate engineer ing contr ols
Engineer ing Measur es Showers
Eyewash stations
Ventilation systems
Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible
exposure limits. Ensure adequate ventilation.
Individual pr otection measur es, such as per sonal pr otective equipment
Eye/Face Pr otection:
Tightly sealed goggles
Body pr otection:
Protective work clothing.
Skin protection:
Pr otective gloves
Mater ial of gloves: