SDS
SAMSUNG SDI Co., Ltd.
Date: January 1
st
2020 Revision no.: 01
MODEL INR18650-29E
Page 13 of 29
- Dimethyl carbonate : In the skin irritation test using rabbits, the test material was not irritating. (OECD
Guideline 404)
- Polyethylene : In the skin irritation test using rabbits, the test material was mildly irritating.
- Ethylene carbonate : In the skin irritation test using rabbits, the test material was not classified.
(OECD Guideline 404, GLP)
- Lithium hexafluorophosphate(1-) : In the skin irritation test using human skin model, the test material
was corrosive. (EU Method B.40, GLP)
- Graphite : In the skin irritation test with rabbits, the test material was not irritating. (OECD Guideline
404, GLP)
- Ethyl methyl carbonate : In the skin irritation test using rabbits, the test material was not irritating.
(OECD Guideline 404, GLP)
- Nickel : Industrial nickel dust causes nickel dermatitis.
- 1-Propene, homopolymer : Processes involved in production&processing of polyolefins are usually
totally enclosed & type of accidents that may occur will be burns to skin or eyes, or asphyxiation or
intoxication dueto inhalation of vapors escaping from leaks.
- 1-methyl-2-pyrrolidone : In the skin irritation test using rabbits, the test material was not irritating.
(OECD Guideline 404)
- Nickel sulphide : In the skin irritation test using rabbits, the test material was slightly irritating. The
mean erythema score is 0.3 at 24 and 48h, and 0 at 72h. The effects are fully reversible within 72
hours. (OECD Guideline 404, GLP) (Read-across; Nickel subsulfide)
- Silicon : In the skin irritation test using rabbits, the test material was not irritating. (OECD Guideline
404, GLP)
- Trade secret 2 : In the skin irritation test using human skin model, the test material was irritating.
(OECD Guideline 439, GLP)
- Lithium carbonate : In the skin irritation test using rabbits, the test material was not irritating. (OECD
Guideline 404, GLP)
- Carbon black : In the skin irritation test using rabbits, the test material was not classified. (OECD
Guideline 404)
- Succinonitrile : In the skin irritation test using rabbits, the test material was not irritating. (OECD
Guideline 404)
Serious eye damage/ irritation : Not classified
- Carbon : In the eyes irritation test with rabbits, the test material was slightly irritating. but they were
fully reversible within 7 days. (OECD Guideline 405, GLP)
- Iron : In the eye irritation test using rabbits, the test material was not irritating. (OECD Guideline 405)
- Copper : In the eyes irritation test with rabbits, the test material was irritating. but it was fully reversible
within 7 days. (OECD Guideline 405, GLP)
- Aluminium : In the eye irritation test using rabbits, the test material was not irritating. (Read-across)
- Cobalt lithium dioxide : In the eye irritation test using rabbits, the test material was not irritating.
(OECD Guideline 405, GLP)
- Dimethyl carbonate : In the eye irritation test using rabbits, the test material was not irritating. (GLP)
- Polyethylene : In the eye irritation test using rabbits, the test material was mildly irritating.
- Ethylene carbonate : In the eye irritation test using rabbits, the test material was mildly irritating.
(OECD Guideline 405, GLP)
- Lithium hexafluorophosphate(1-) : In the eye irritation test using fertilised brown leghorn chicken eggs,
the test material was severely irritating. (GLP)