SDS

SAMSUNG SDI Co., Ltd.
Date: January 1
st
2020 Revision no.: 01
MODEL INR18650-29E
Page 11 of 29
- Keep away from heat/sparks/open flames/hot surfaces. No smoking.
- Friction, heat, sparks or flames
- Dusts or shavings from borings, turnings, cuttings, etc.
- Do not exceed manufacturer’s recommendation for charging or use battery for an application for which
it was not specifically designed.
- Do not electrically short.
10.5 Incompatible materials
- Avoid contact with acids and oxidizers.
- Keep away from any possible contact with water, because of violent reaction and possible flash fire.
- Handle under inert gas. Protect from moisture.
- Combustibles, reducing agents
10.6 Hazardous decomposition products
- None under normal conditions.
- Corrosive and/or toxic fume
- Material may produce irritating and highly toxic gases from decomposition by heat and combustion
during burning.
- Irritating and/or toxic gases
Section XI TOXICOLOGICAL INFORMATION
This is a product that fulfills a certain function in solid state with specific shape without dischar
ging any chemical substance in its use and has no obligation to write (M)SDS. Since this docume
nt contains the precautions for safe handling related to its materials or chemical substances consis
ting of this product, please note that these overall information is irrelevant to this product.
11.1 Information on toxicological effects
Acute toxicity
Oral : Not classified (ATEmix = 1001 mg/kg bw)
- Carbon : Rat LD
50
> 2000 mg/kg (OECD Guideline 423, GLP)
- Iron : Rat LD
50
= 98600 mg/kg (OECD Guideline 401, GLP)
- Copper : Rat LD
50
= 481 mg/kg (OECD Guideline 401, GLP)
- Aluminium : Rat LD
50
> 15900 mg/kg (Read-across)(OECD Guideline 401)
- Cobalt lithium dioxide : Rat LD
50
> 5000 mg/kg (OECD Guideline 425, GLP)
- Dimethyl carbonate : Rat LD
50
> 5000 mg/kg (male/female)(OECD Guideline 401, GLP)
- Polyethylene : Rat LD
50
> 2000 mg/kg
- Ethylene carbonate : Rat LD
50
= 10400 mg/kg (OECD Guideline 401)
- Lithium hexafluorophosphate(1-) : Rat LD
50
= 50~300 mg/kg (OECD Guideline 423, GLP)
- Graphite : Rat LD
50
> 2000 mg/kg (OECD Guideline 423, GLP)
- Ethyl methyl carbonate : Rat LD
50
> 5000 mg/kg (OECD Guideline 401, GLP)
- Nickel : Rat LD
50
> 9000 mg/kg (OECD Guideline 401, GLP)
- 1-methyl-2-pyrrolidone : Rat LD
50
= 4150 mg/kg (OECD Guideline 401)
- Nickel sulphide : Rat LD
50
> 5000 mg/kg (OECD Guideline 401, GLP)