Operation Manual

121
User Manual
1. if there is a C-CARD inserted in the slot and there is not a malfunction, the name of
the C-CARD zone and the message "OK" are shown.
2. if there is a C-CARD inserted in the slot, but it is a damaged C-CARD, the name of
the C-CARD zone and the message "Faulty" are shown.
3. if there is not any C-CARD inserted in the slot, the message "not present" is shown.
4. if there is an User C-CARD inserted in the slot, the message "USER C-CARD" is
shown.
C-CARD Connector
Indicates if there is a malfunction in the connector. It is used only in production.
6.7.4 SERIAL PORTS
If you are having problems receiving data from the position-finding instrument,
this test should help determine the problem.
Change Parameters
To change the parameters of the serial interface. This menu allows to select the Port 1,
2, 3, the Baud Rate between 4800 or 9600, the Data Bits (Word Length) between 7 or
8, the Parity between even, odd or none, the Stop Bits between 1 or 2. Default settings
are: Port = Port2, Baud Rate = 4800, Data Bits = 8, Parity = none, Stop Bits = 1.
Input Data Display
Allows the chart plotter to act as a computer terminal and display the incoming data
exactly as it received.
If the data displayed on the screen is unrecognizable, you may have selected the wrong
input parameters for your particular receiver. Check your receiver manual to be sure
that you have selected the proper interface format. If the screen is blank, you may have
a broken connection and no data is being received.
Use 'ZOOM IN' to stop (or continue after pause) data displaying, 'ENTER' to show
data in hex or ASCII mode (normal or small) and 'CLEAR' to exit.
6.7.5 MODEM TEST
To check the Modem connections. Press 'ENTER' to select the preferred Port related
to the connections made, to the Port that the Modem C-COM is connected.
6.7.6 EXTERNAL ALARM
To check if the External Alarm has been transmitted.