Operation Manual

134 User Manual
Fig. 7.4g - External NMEA Connection on Port 1 FOR COMPACT X7 FISH
QUICK DISCONNECT BRACKET CABLE
DESCRIPTIONWIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
POWER SUPPLY GND
POWER SUPPLY+
C-COM
C-COM
C-COM
POWER GND
POWER +10-35Vdc
INPUT 1+
COMMON
OUTPUT 1+
FUNCTION
C-COM GSM Plus CABLE
WIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
GND
POWER SUPPLY+
C-COM TX+
C-COM TX-
C-COM RX+
FUNCTION
Fig. 7.4h - C-COM Connection on Port 1
7.5 TROUBLESHOOTING
The following is a brief guide to some of the problems you may experience while
using the chart plotter with common solutions.
7.5.1 PROBLEMS AND SOLUTIONS
The chart plotter does not turn On — Make sure that the correct voltage (10-35 volt dc)
is present. Check also that the polarity is correct. Refer to the Par. 2.2.
The chart plotter does not turn Off — If, after a 'POWER' pressure (for at least 3
seconds) the chart plotter does not turn Off, then turn Off the voltage.
The chart plotter does not respond to any command Try to turn Off, and then turn
On. If the problem persists, erase the memory (see Par. 6.6.1).
The chart plotter does not get a valid fix — Make sure that no metal obstacle is placed
around the chart plotter acting as a shield for the antenna. If, after 15 minutes, the chart
plotter does not get the fix, turn it Off and On again.