User's Manual

7
On the front panel of the LORENZ DEEPMAX Z2
there are three push buttons to change or alter the
functions, retune the Z2 to the ground or storing
eld data when the data logger is turned on:
ZERO retunes the Z2 or starts the two step auto
ground function when pressed for a longer duration.
MENU/ GADJ opens the Menu or starts the manual
ground adjust when pressed for a longer duration
and a GND function is currently active.
OFF/ FIELD turns the detector o or stores the eld
data when data logger is on.
1. Pull the two carrying straps of the belt pad
through the gaps of the control housing and the
pad again. Mount the two plastic connectors at the
two sides that they are secure and will not come o.
Fix the smaller straps at the top of the Z2 control box.
Put on the complete carrying straps with the two
belt pads and adjust all straps to comfortable lengths.
2. Mount the search coil with the lower bre glass
rod, x the other two rods and adjust to t to your
length. Make sure that the connection cable is laid
around the rods without any tension.
3. Connect the coil to the Z2 electronics unit after-
wards. If additional Battery + GPS module is in use,
fasten the same by sliding it from the top in the two
mounting plates at the rear belt pad and connect
the same with the Z2. Disconnect everything when
planning to store.
4. Press
MENU and OFF for 2 seconds to turn on
the Z2, when LOW BAT appears in the display char-
ge the battery rst. With
OFF the Z2 can be turned
OFF again.
5. To start the automatic two steps Ground Balance
hold the coil in the air horizontally and about one
meter from the ground and press
ZERO until a high
beep sound is coming. Afterwards lower the coil
to the ground at a place with no metal and press
ZERO again until a second low beep sound appears,
while keeping the coil steadily in the same position.
Arrows pointing up- and downwards indicate the
position of the coil. While searching it might be
necessary to press the same
ZERO button shortly to
recall the audio threshold setting during operation.
3. LORENZ DEEPMAX Z2 INSTRUCTIONS