Owner manual

Commands for Host-Processed Modems Reference Manual
3-42 Conexant 100498E
+ER - Error Control Reporting
This extended-format numeric parameter controls whether or not the extended-format "+ER: "
intermediate result code is transmitted from the modem to the DTE (see Section 3.4 and
Table 3-15).
S95 bit 3 is reset to 0 for +ER=0 and is set to a 1 for +ER=1. The more recent setting of +ER
or S95 bit 3, and the W command setting, determines the actual error control result code
reporting (see S95 Parameter and W Command).
Syntax
+ER=[<value>]
Defined Values
<value> A decimal number corresponding to the selected error control
option:
0 Error control reporting disabled (no +ER
intermediate result code transmitted).
1 Error control reporting enabled (+ER intermediate
result code transmitted). (Default.)
Reporting Current or Selected Values
Command: +ER?
Response: +ER: <current value>
Example: +ER: 1 for the default setting
Reporting Supported Range of Parameter Values
Command: +ER=?
Response: +ER: (<value> range)
Example: +ER: (0,1)