Data Sheet
- PERFORMANCE DATA
Discharge Rates in Watts to Various End Voltages at 25
℃(77℉)
End Voltage
Time
1.85V 1.80V 1.75V 1.70V 1.67V 1.65V 1.60V
5 min 36.3 39.5 41.5 43.5 44.3 45.5 47.0
10 min 25.7 27.7 29.2 30.2 30.7 31.3 32.3
15 min 19.7 21.2 21.8 22.5 22.8 23.2 23.7
30 min 11.2 11.7 12.1 12.5 12.7 12.8 12.9
60 min 5.95 6.27 6.47 6.70 6.82 6.93 7.07
120 min 3.13 3.38 3.53 3.65 3.72 3.80 3.92
180 min 2.53 2.72 2.85 2.97 3.02 3.07 3.15
240 min 2.02 2.15 2.27 2.33 2.37 2.40 2.45
300 min 1.73 1.87 1.95 1.98 2.00 2.02 2.05
600 min 1.01 1.09 1.15 1.17 1.18 1.19 1.21
1200 min 0.530 0.572 0.603 0.615 0.620 0.625 0.633
- Discharge Rates in Amperes to Various End Voltages at 25℃(77℉)
End Voltage
Time
1.85V 1.80V 1.75V 1.70V 1.67V 1.65V 1.60V
5 min 17.8 21.7 23.9 25.8 26.4 27.0 27.8
10 min 13.2 14.8 15.7 16.2 16.6 16.9 17.3
15 min 9.92 10.5 10.9 11.1 11.2 11.3 11.5
30 min 5.84 6.15 6.26 6.38 6.42 6.47 6.55
60 min 3.04 3.20 3.38 3.46 3.49 3.53 3.59
120 min 1.58 1.70 1.79 1.87 1.91 1.94 1.99
180 min 1.27 1.35 1.41 1.47 1.49 1.52 1.55
240 min 1.00 1.07 1.11 1.15 1.16 1.18 1.21
300 min 0.851 0.898 0.919 0.942 0.953 0.962 0.978
600 min 0.497 0.506 0.514 0.521 0.524 0.529 0.535
1200 min 0.268 0.274 0.279 0.284 0.286 0.287 0.291
All data on the spec. sheet is an average value:
The tolerance range : X<6min(+15%~-15%), 6min≦X<10min(+12%~-12%),10min ≦X < 60min(+8% ~-8%), X≧60min(+5%~-5%)
211016-1F
Head Quarter Service - TEL: +886-49-2254-777 FAX: +886-49-2255-139 E-mail: sales@mail.klb.com.tw
USA Customer Service - TEL: +1-949-328-7936 FAX: +1-949-266-9917 E-mail: sales@kunglong.com
Vietnam Customer Service - TEL: +84-72-3779666 FAX: +84-72-3779476 E-mail: sales@mail.klb.com.tw
Contents in this data sheet are subject to change for improvement without prior notice to users. For clarifications and updated information, please contact us.
-20 -10 0 10 20 30 40 50
℃
-4 14 32 50 68 86 104 122
℉
Temperature
Effect of Temperature on Capacity 25 (77 )
℃℉
0
20
40
60
80
100
120
C
a
p
a
c
i
t
y
%
0.05CA
0.1CA
0.25CA
0.6CA
1CA
2CA
40 (104 )
℃℉
30 (86 )
℃℉
20 (68 )
℃℉
10 (50 )
℃℉
0(32)
℃℉
Capacity Retention Characteristic
Storage Time (months)
Re
m
aining Capacity
369121518
0
25
50
75
100
(%)
W
P5-12
Trickle (or float) Service Lif
e
Ambient Temperature
L
i
f
e
(
y
e
a
r
s
)
0.5
30 40 50 ( )
℃
68 86 104 122 ( )
℉
2
5
10
20
3
0 200 400 600 800 1000 1200 1400 1600
20
40
60
80
100
120
C
a
p
a
c
i
t
y
%
Number of Cycles (times)
Cycle Service Lif
e
(1) Discharge : 0.17CA
(2) Charge : CV 2.4V/cell 16H Imax 0.3CA
(3) End of life discharge voltage : 1.65 Vpc
(4) Temperature : 25 2
*
±℃
Discharge Depth 100%
Discharge Depth 50%
Discharge Depth 30%