User Manual

Sitter II
4
Programming Pagers
The Program Pager ID Screen sets up and loads the pager functions into the staff pagers. The serial cable must be
connected from the computer to the Sitter II.
To program Over the Air Programmable pagers (Note: Non Over the Air
Programmable Pagers are programmed on a separate fixture):
1. Be sure the pagers have new batteries and are turned off (the word OFF
appears in the display).
2. Enter the System ID
(system number, default = 0) to be assigned to the
pager you are programming. . Caution: Setting this ID also changes the
System ID of the Sitter II. Be sure the System ID of the pagers match the
System ID of the Sitter II you are using.
3. Enter the Pager ID
(pager number) to be assigned to the pager you are
programming.
4. Enter the All Page ID
(All page number, default 911) to be assigned to the
pager you are programming.
5. Press the ON/OFF
key on the pager until it vibrates and beeps.
6. When the pager stops beeping, press the Send button.
7. After the pager has programmed turn it off (The pager will beep 3 sets of 2 beeps during programming).
8. Repeat with all remaining pagers.
9. When finished press Done.
10. Turn on the pagers and page them one by one to ensure they are properly programmed.
Help Menu
The Help drop down menu enables the HELP file which contains all the information in this manual.
Tools Menu
The tools menu is used to initialize the Sitter II to the original factory defaults. This eliminates any corrupted data that may
be in the unit .