OXY-REG with DO-SET (optional)
Oxygen Analyzer and Regulator System
User manual version 2.4.1
The OXY-REG system is used for monitoring and regulating dissolved oxygen content of sea or
fresh water in fish tanks, respirometers, aquaria etc.
LIST OF PARTS
1) Controller instrument
2) Data cable
3) MINI-DO galvanic cell oxygen probe
4) Maintenance kit for O
2
probe
5) Membrane tool
6) Power cord
7) Converter piece
8) User manual
9) DO-SET (OPTIONAL)
- Solenoid valve w/push-in fittings
- PU tubing
- Air stone
CONTENTS
LIST OF PARTS .............................................................................................................. 1
CONTENTS ................................................................................................................... 1
SETUP .......................................................................................................................... 2
CONFIGURATION / OPERATING THE FUNCTION KEYS ........................................................ 3
CALIBRATING THE OXYGEN PROBE .................................................................................. 6
MAINTENANCE .............................................................................................................. 7
RENOVATING PROBE ..................................................................................................... 7
USING THE RELAYS ....................................................................................................... 8
FAST SET POINT ADJUSTMENT ........................................................................................ 3
PASSWORD PROTECTION ............................................................................................... 9
DEFAULT SETTINGS ..................................................................................................... 10
USING THE CONTROLLER FOR DATA ACQUISITION ......................................................... 10
CHANGE OXYGEN UNITS .............................................................................................. 10
OXY-REG SPECIFICATIONS ........................................................................................... 11
MINI-DO SPECIFICATIONS ........................................................................................... 11