Quick Start Guide Version C - August 2022 www.logtag-recorders.
Quick Start Guide Contents What's Included 3 Battery Installation 4 Running the Connection Wizard 5 Connecting to your WiFi Network 8 LogTag Online Remote Configuration 10 Downloading LogTag Analyzer 14 Configuration through LogTag Analyzer 15 Installing the Wall Mount 16 Starting your UTREL30-WiFi 17
What's Included Please check you have each of the items shown below before continuing with setting up your UTREL30-WiFi.
Battery Installation A permanent power supply should be connected to the USB socket at the bottom of the device. Two AAA batteries are required as the back up source to ensure your device continues to log in the event of a power outage or accidental removal of power. 1. Remove the back cover of the UTREL30-WiFi case using the Phillips (cross-shaped) screwdriver. 2. Install the two AAA batteries taking note of the direction to install each battery. 3.
Running the Connection Wizard Alternatively, to connect your logger using Bluetooth® connection capablities on the LogTag Mobile application refer too the Bluetooth® Connection Guide. Note: Please ensure there is internet connection on your computer prior to starting this process. Download the latest Connection Wizard from the LogTag website. https://logtagrecorders.com/download/software/ connectionwizard.exe 1. Select Start and follow the instructions.
Running the Connection Wizard (continued) 2. Sign in with your LogTag Online account and select SIGN IN. Select the Create a LogTag Online Account if you do not have an account. You can also click or copy the following link and follow the on-screen instructions; https://logtagonline.com/signup Note: If you selected Skip, you will need to manually register the device on LogTag Online or repeat the LogTag Online Connection Wizard.
Running the Connection Wizard (continued) 3. The Connection Wizard will scan for connected LogTag devices. Your device will be automatically registered to your LogTag Online account as soon as your device has been identified. Select Scan Again if your device was not found. Double-check your devices are plugged-in to your computer using the USB cable provided before scanning again.
Connecting to your WiFi Network 4. Connect your device to the network by selecting your Wi-Fi network name (or SSID) and providing the network password, then select Next. Passwords are case-sensitive. Select the eye icon to view the password you entered. Note: Incorrectly entered password is a common reason why your device failed to connect to your network. Some Wi-Fi Networks won’t appear in this list for security purposes.
5. Your device will connect to your local network using the provided Wi-Fi credentials (network name or SSID and password). It will also check its’ connection to LogTag Online. This typically takes 10 seconds. Select Close once the connection was successful. Select Again to repeat the steps to connect to your network. 6. Select the LogTag Online Sign In page link to login to LogTag Online.
Remote Configuration through LogTag Online LogTag Online is a secure online application that stores the data recorded from your logger against your account. Once your device is connected to your network, it can be configured remotely through LogTag Online. Profile and timezone can be configured for the logger. Ensure your device is plugged-in to your computer using the USB cable provided.
Remote Configuration through LogTag Online (continued) Signing in to your LogTag Online Account 1. Login to LogTag Online; https://logtagonline.com The location for the first channel will be displayed in the pinned locations of the Dashboard.
Remote Configuration through LogTag Online (continued) Manually register your device if you cannot see the location. The second location will need to be created manually. Each channel can be assigned to its location. Please refer to the Activation Codes section in the LogTag Online User Guide for more information. The probe inserted into the loggers CH2 port will automatically register as CH1 in the location description when only one probe is inserted into the logger.
Remote Configuration through LogTag Online (continued) 3. In the settings tab of the Location Details screen, select the profile to apply to your logger from the Logger Configuration Profile drop-down that best suits your needs. 4. Select the time zone for the location from the Logger Timezone drop-down. 5. Select Save to apply the configuration. 6. Navigate to the Devices tab and select on your devices name. The configuration profile will be shown along with its current status.
Downloading LogTag Analyzer The minimum recommended version is LogTag Analyzer 3.2.0 1. Download LogTag Analyzer from the LogTag website: https://logtagrecorders.com/software/LTA3/ 2. Double-click the downloaded file to open the LogTag Analyzer Setup Wizard and follow the on-screen prompts to install. 3. Select Finish to exit the setup wizard. 4. Open the LogTag Analyzer application.
Configuration through LogTag Analyzer Connect your UTREL30-WiFi to your computer via the USB cable provided. The USB socket on the device is located on the bottom, protected by a rubber seal. 1. Select Configure from the LogTag menu or select the Wizard icon. 2. Adjust your logger configuration settings as required. For more information on configuration settings, please refer to Configuring the UTREL30-WiFi in the Product User Guide or press F1 for help. 3.
Installing the Wall Mount Setup of your UTREL30-WiFi is complete. Attach the Wall Mount Bracket on the side of your refrigerator or freezer, preferably at eye-level with the adhesive strip provided with the Wall Mount. Before sticking on the Wall Mount, make sure the probe cable and the USB cable from the UTREL30-WiFi can both reach the device comfortably without obstruction or at risk of being accidentally disconnected if knocked.
Starting your UTREL30-WiFi Press and hold the START/Clear/Stop button. STARTING will appear along with READY. Release the button once READY disappears. The UTREL30-WiFi now records temperature data. The Logger will not start if: • You release the button before READY disappears. • You keep holding the button for more than 2 seconds after READY disappears. • The backup battery is critically low and the Logger is not connected to power.
Viewing Second Temperature Channel Press the CHANNEL FUNCTION button to change the channel on screen. In this example, the display switched from CH1 to CH2. The device will toggle between the two channels if both external probes are configured. Note: The probe cover can be inserted in an unused channel port.