2.2 Power Supply Connection
Allowed supply voltage: 12-24V +/-5%.
System's DC supply connector: male jack size 5.5*2.1mm.
Use of higher supply voltage can damage the system!!
Use only authorized class B power supply certified device.
The current consumption of the device (with GPRS connection)
is 0.3A@12V.
2.3 Ethernet connection
Use CAT5E cable, shielded SFTP.
2.4 RS232 interface
Standard RS232, port settings:
baud rate 115200b/s
data bits=8
parity=none
stop bit=1
flow control=none
Use standard cable with male D-type 9 pin connector, pin out:
Pin 2-Tx
Pin 3-Rx
Pin 5 – GND
2.5 GPRS antenna connection
In StockBox systems with the optional GPRS module installed,
connect the GPRS antenna supplied with the system and mount it
on the system enclosure or any near-by allowed surface.
2.6 RFID transponders
The system supports ISO15693 transponders.