Installation Instructions
2
CaretakerSentry®
v3.10
THESE INSTRUCTIONS ARE FOR THE DEALER. REFER TO THE “QUICK
START GUIDE” FOR BASIC INSTALLATION.
These instructions are for the Dealer to set-up and program the CaretakerSentry System to operate with the Central
Station of your choice.
The CaretakerSentry product (the “System”) uses the industry standard “Contact ID” and “4+2” protocols.
Voice prompts provide easy set-up and testing.
Basic set-up requires you to:
• Install the 4 AA rechargeable Ni-MH batteries in the Base unit.
• Plug the base unit into AC power (not a switched outlet)
• Connect to a wired telephone connection – Line In
Basic programming requires you to enter:
•Thecentralstationtelephonenumber(s).
•The4digitaccountcodeofyourcustomer.
There are several special options you can set for additional features - these include:
• Changing the 4 digit factory passcode to a passcode of your choice – to prevent unauthorized reprogramming
• You should enter two telephone numbers - the primary number should be the alarm receiver’s toll free number
andthesecondarynumbershouldbethealarmreceiver’slocallongdistancenumber,incasetherstnumberis
busy or unreachable.
• You can program the System to send Restore Codes.
• You can program the System to send a Periodic Test Signal Every Day, Every Week or every 30 days.
• The System can learn up to a total of 9 Pendants.
NOTE: At any time in the future, you can remotely change all of these setting over a telephone line using any touch-
tone phone.
NOTICE - Please read all of the Limitations of Liability, Disclaimer and Limited Warranty that are in the User Quick Install
Guide.