Product Info

Report No: CCISE191202301-V01
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1912023
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com Page 95 of 171
Test Laboratory: CCIS Date/Time: 12.13.2019 17:04:38
DUT: 5.99 inch 4G Smart Phone; Type: L60; Serial: 1#
Communication System: UID 0, GSM (0); Frequency: 824.2 MHz; Duty Cycle: 1:8.30042
Medium parameters used: f = 825 MHz; σ = 0.975 S/m; ε
r
= 54.731; ρ = 1000 kg/m
3
Phantom section: Flat Section
DASY5 Configuration:
Probe: EX3DV4 - SN3924; ConvF(9.72, 9.72, 9.72); Calibrated: 08.30.2019;
Sensor-Surface: 1.4mm (Mechanical Surface Detection)
Electronics: DAE4 Sn1373; Calibrated: 08.09.2019
Phantom: ELI v5.0; Type: QDOVA002AA; Serial: TP:1208
Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)
GSM 850 Body Back/Low Channel/Zoom Scan (5x5x7)/Cube 0: Measurement
grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 22.22 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.594 W/kg
SAR(1 g) = 0.409 W/kg; SAR(10 g) = 0.293 W/kg
Maximum value of SAR (measured) = 0.522 W/kg
GSM 850 Body Back/Low Channel/Area Scan (51x81x1): Interpolated grid:
dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.529 W/kg
0 dB = 0.529 W/kg = -2.77 dBW/kg