Product Info

Report No: CCISE191202301-V01
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1912023
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: info@ccis-cb.com Page 59 of 171
15.4 Repeated SAR measurement
Band/ Mode
Test Position
CH.
Freq.
(MHz)
Measured SAR (W/kg)
Original
1
st
Repeated
2
nd
Repeated
Value
Ratio
Value
Ratio
Band II/RMC
Back
9400
1880.0
0.869
0.864
1.01
/
/
Band2/RB#0
Back
18900
1880.0
0.948
0.938
1.01
/
/
Band2/RB#0
Bottom
18900
1880.0
0.876
0.862
1.02
/
/
Band2/50%RB#24
Back
18900
1880.0
0.839
0.832
1.01
/
/
Band2/100%RB#0
Back
18900
1880.0
0.844
0.836
1.01
/
/
ANSI / IEEE C95.1 SAFETY LIMIT
Spatial Peak
Uncontrolled Exposure/General Population
1.6 W/kg (mW/g)
Averaged over 1g
Note:
1. Per KDB 865664 D01v01r04, for each frequency band, repeated SAR measurement is required only when the
measured SAR is ≥0.8 W/kg
2. Per KDB 865664 D01v01r04, if the ratio of original and repeated is ≤ 1.2 and the measured SAR <1.45 W/kg, only one
repeated measurement is required.