4 SAR Results Summary
The maximum results of Specific Absorption Rate (SAR) found during test as bellows:
<Highest Reported standalone SAR Summary>
Exposure Position
Frequency Band
Reported 1-g SAR
(W/kg)
Equipment Class
Highest Reported
1-g SAR (W/kg)
Head
GSM 850
0.260
PCE
0.562
GSM 1900
0.129
WCDMA Band V
0.288
WCDMA Band II
0.209
LTE Band 2
0.283
LTE Band 4
0.299
LTE Band 5
0.342
LTE Band 7
0.562
WLAN 2.4 GHz
0.501
DTS
Body
(10 mm Gap)
GSM 850
0.411
PCE
1.037
GSM 1900
0.570
WCDMA Band V
0.553
WCDMA Band II
0.948
LTE Band 2
1.037
LTE Band 4
0.736
LTE Band 5
0.676
LTE Band 7
0.542
WLAN 2.4GHz
0.135
DTS
Hotspot
(10 mm Gap)
GSM 850
0.481
PCE
1.037
GSM 1900
0.529
WCDMA Band V
0.553
WCDMA Band II
0.948
LTE Band 2
1.037
LTE Band 4
0.736
LTE Band 5
0.676
LTE Band 7
0.542
WLAN 2.4 GHz
0.135
DTS
<Highest Reported simultaneous SAR Summary>
Exposure Position
Frequency Band
Reported 1-g SAR
(W/kg)
Equipment Class
Highest Reported
Simultaneous
Transmission
1-g SAR (W/kg)
Back
LTE Band 2
1.037
PCE
1.172
WLAN 2.4 GHz
0.135
DTS
Note:
1. The highest simultaneous transmission is scalar summation of Reported standalone SAR per FCC KDB 690783 D01 v01r03, and
scalar SAR summation of all possible simultaneous transmission scenarios are < 1.6W/kg.
2. This device is compliance with Specific Absorption Rate (SAR) for general population/uncontrolled exposure limits (1.6 W/kg)
specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEE C95.1-2005, and had been tested in accordance with the measurement
methods and procedures specified in IEEE 1528-2013.